System instruction manual TeamConnect

Table Of Contents
Specifications
TeamConnect | 67
Operating and storage conditions
Temperature Operation: 0 - +40 °C
Storage: -25 - +70 °C
Relative humidity 95 % (non-condensing)
In compliance with
Europe
EMC:
EN 55103-1/-2
Safety:
En 60065
USA 47 CFR 15 subpart B
Canada CAN ICES-3 (B)/NMB-3(B)
SL Mic Hub 1
Housing metal
Dimensions 144 x 76.3 x 31.5 mm
Ports
4x Mic 5-pin terminal connector
2x Connect/Status 6-pin terminal connector
1x Mute 7-pin terminal connector
1x Audio RJ-45
Power supply
The SL Mic Hub 1 ist connected to the Combox (SL TeamConnect CB1) via a 6-pin
terminal connector cable. The Combox delivers the necessary power supply to
operate the bi-color status LEDs of the mute button MAS 1 TC and the hook
button MAS 2 TC.
The Combox supplies sufficient power for up to 5 MAS 1/2 buttons. If you want
to use more than 5 buttons in your setup, you need to connect an external power
supply (5 V, >100 mA, recommended Sennheiser Power supply Art. No. 534480)
to pin 6 and 7 of the MUTE socket.
MAS 1 TC | MAS 2 TC
Supply voltage 5 V (12 mA max.)
Connector XLR-5M
Pin assignment XLR-5M out
1 = Switch
2 = Switch
3 = LED red -
4 = LED green -
5 = LEDs +5 V in
LED light ring color red / green
TTL levels for LED activation 12 V
Current consumption LED ring 12 mA
Weight 60 g
Height 81 mm (8 mm above surface)
Diameter 28.5 mm
Thread M 20
Operating temperature -10 °C to +50 °C