System instruction manual TeamConnect
Table Of Contents
- Important safety instructions
- Package contents
- How to read this manual
- Using the TeamConnect system
- The TeamConnect components
- TeamConnect Central Unit
- TeamConnect Combox
- Microphone Hub
- SpeechLine microphones and microphone accessories
- SpeechLine active loudspeakers
- Configuration Manager software
- SL TeamConnect CU1 - Product overview
- SL TeamConnect CB1 - Product overview
- SL Mic Hub 1 - Product overview
- Installing the SL TeamConnect CU1
- Establishing a network connection
- Connecting the SL TeamConnect CU1 to the telephone landline network
- Connecting the SL TeamConnect CB1 to the SL TeamConnect CU1
- Installing the SL TeamConnect CB1 in a meeting room
- Using the GPIO port of the SL TeamConnect CB1
- Connecting a computer
- Connecting a headset or an enterprise telephone
- Connecting the SL TeamConnect CU1 to a media control system
- Connecting and positioning microphones
- Connecting microphones using the SL Mic Hub 1
- Connecting microphones directly to the SL TeamConnect CU1
- Connecting auxiliary audio devices
- Connecting audio output signals
- Preparing the Quick Guide and the Room Sticker for the user
- The Configuration Manager software
- Installing the Configuration Manager software
- Connecting a computer for configuring the system
- Navigating the Configuration Manager software
- Configuring the SL TeamConnect CU1
- Configuring microphone settings
- Configuring audio processing settings
- Configuring line input settings
- Configuring audio output settings
- Configuring teleconference settings
- Configuring the settings of the SL TeamConnect CB1
- Configuring communication settings
- Using the Device Toolbox
- Using the Mixer Console
- Using presets
- Specifications
- Manufacturer Declarations
60 | TeamConnect
The Configuration Manager software
Virtual Reference outputs
The Virtual Reference outputs allow the combination of multiple audio sources to
create a single combined audio signal which can be used as the reference signal
for echo cancellation.
To combine the desired audio signals as a single virtual reference in the
Mixer Console:
X Route the desired audio signals to the desired Virtual Ref channel in the Mixer
Console.
All channels routed to the respective Virtual Ref channel in the Mixer Console
will be treated as one combined audio signal for echo cancellation reference.
To specify the desired virtual reference channel as reference for echo cancellation:
X Open the Mic Settings configuration window (see page 47).
X Navigate to the Processing tab.
X Select Virtual Ref 1 or Virtual Ref 2 in the AEC/PA Reference 1 or
AEC/PA Reference 2 dropdown menu.
The selected virtual reference channel is used as reference for echo cancellation.