Instruction manual ew 300-500 G4
Using the EM 300-500 G4
94
▷ Press the SYNC button to synchronize the selected frequency with the
transmitter immediately.
Current List
▷ Select Current List to show the list of unused frequencies from the last
scan.
Reset
▷ Select Reset List to delete the list of unused frequencies.
Performing multi-channel frequency setup
As an alternative to the following procedure, multi-channel frequency
setup can also be performed using the Sennheiser Wireless Sys-
tems Manager (WSM) software. For more information about con-
trolling devices via the Sennheiser Wireless Systems Manager (WSM)
software, refer to the instruction manual for the software. You can down-
load the software here:
www.sennheiser.com/wsm
To perform the automatic frequency setup for multiple radio links simulta-
neously:
▷ Connect all of the receivers to one network using a network switch. See
“Creating a data network”.
▷ Please note that all receivers must be in the same IP address range.
• The IP addresses can be automatically assigned if there is a DHCP
server in the network.
• If there is no DHCP server in the network, the IP addresses must be
assigned manually. See “Advanced -> IP Address menu item”.
• Assign the IP addresses for all receivers in the 192.168.x.x range (the
link-local range 169.254.x.x is also a possible alternative).
▷ Open the Easy Setup menu item on one of the receivers.
This receiver is the master. You can choose any receiver to be the mas-
ter.
▷ Perform the frequency scan on the master receiver as described above.
▷ From the scan results in the master receiver, select a frequency bank