Instruction manual ew 300-500 G4

Using the EM 300-500 G4
94
Press the SYNC button to synchronize the selected frequency with the
transmitter immediately.
Current List
Select Current List to show the list of unused frequencies from the last
scan.
Reset
Select Reset List to delete the list of unused frequencies.
Performing multi-channel frequency setup
As an alternative to the following procedure, multi-channel frequency
setup can also be performed using the Sennheiser Wireless Sys-
tems Manager (WSM) software. For more information about con-
trolling devices via the Sennheiser Wireless Systems Manager (WSM)
software, refer to the instruction manual for the software. You can down-
load the software here:
www.sennheiser.com/wsm
To perform the automatic frequency setup for multiple radio links simulta-
neously:
Connect all of the receivers to one network using a network switch. See
“Creating a data network”.
Please note that all receivers must be in the same IP address range.
The IP addresses can be automatically assigned if there is a DHCP
server in the network.
If there is no DHCP server in the network, the IP addresses must be
assigned manually. See “Advanced -> IP Address menu item”.
Assign the IP addresses for all receivers in the 192.168.x.x range (the
link-local range 169.254.x.x is also a possible alternative).
Open the Easy Setup menu item on one of the receivers.
This receiver is the master. You can choose any receiver to be the mas-
ter.
Perform the frequency scan on the master receiver as described above.
From the scan results in the master receiver, select a frequency bank