Installation manual
D
IGIPLEX
NE C
ONTROL
P
ANEL
13
Figure 3-6: Single Zone Input Connections
3.14 D
OUBLE
Z
ONE
C
ONNECTIONS
Enabling the ATZ feature (see section 5.2) allows you to install two
detection devices per input terminal. Connect the devices as shown in
Figure 3-7. Devices connected to input terminals must be assigned to a
zone and the zone's parameters must be defined (see Zone Programming
on page 16). For UL listed installations, use EOL resistor part
#2011002000.
Figure 3-7: Double Zone Connections
3.15 C
ONNECTING
THE
DGP2-ZX4
The 4-Zone Hardwire Expansion Module (DGP2-ZX4) provides four
additional hardwired input terminals (8 zones with ATZ enabled). It
connects directly to the control panel through its on-board
EXPANSION
connector as shown in Figure 3-3: on page 10. Connect detection devices
to the DGP2-ZX4's terminals in the same way that they are connected to
the control panel as shown in Figure 3-6 or Figure 3-7 on page 13. Devices
connected to hardwired input terminals must be assigned to a zone and the
zone's parameters must be defined (Zone Programming on page 16). For
the 4-Zone Hardwire Module (APR3-ZX4), refer to the DigiplexNE Modules
Programming Guide.
Enable ATZ (see section 5.2 on page 17)
and connect as follows (extra input
cannot be used)