User`s manual

19
Functions/Features:
Monitor and control indoor fire risks, for indoor use only, generally set as a 24 hour Defense Line.
Replace the battery every 2 years (varies on usage).
Usually installed to ceilings of living room, hallways, aisles, etc.
Functions as a standalone smoke alarm
Specifications:
Operating power: 9V Battery (Recommend: alkaline battery)
Wireless Transmitting distance: 300ft (in open area)
Service life: 2 years
Monitor volume: 480ft3
Alarm sound: 70dB (built-in)
Installation and Usage:
Smoke sensor may not be part of the standard package for Air-Alarm series and may need to be added to the alarm
host. To add the Smoke sensor to the host, please follow the “To Add:” procedures below. After pairing the sensor, find a
suitable location to mount the mounting bracket with the two screws provided. Recommended location to mount on room
ceiling, aisles ceiling or entry ceiling areas. Next, match the socket grooves of the Smoke sensor to the mounted bracket
and turn clockwise to secure.
After pairing and installing the smoke senor, the sensor will detect smoke covering an area of 480 cubic feet. The smoke
sensor can then set off the alarm when smokes filled the photo electric cylinder chamber that is built inside the smoke
sensor. Once the chamber is filled with certain volumes of smokes, the sensor will send the alarming signal to the alarm
host to sound off the siren(s) to warn there is smoke in the premise.
Adding and Cancelling Smoke Alarm:
To Add:
Step 1: Press PRGM + Password + ENT + 70 + ENT+ XX + ENT
The “ ” light will appear solid blue.
[The XX indicate zone number of the 24 hour defense line, including zones 01 through 05].
Step 2: Press the “Test Button” twice consecutively to trigger the smoke alarm sensor, the alarm host will beep in series,
the “ ” light will flash 5 times and then turn off to indicate the smoke alarm sensor has been successfully added.
To Cancel:
Press PRGM + Password + ENT+71 + ENT+ XX + ENT
The alarm host will beep twice, the “ ” light flash
once and then turn off to indicate the smoke alarm sensor has been successfully cancelled.
Note: The alarm host can only learn 1 wireless device (Smoke Alarm Sensor) at a time, a total of 4 wireless devices
(Sensors) to a zone. If 1 device is removed from a zone that has 4 devices, then all 4 devices in the zone will be
removed, and each device will have to be added again by following the “To Add:” procedure above.