User Manual

13
ENFORCER Access Control Keypad
SECO-LARM U.S.A., Inc.
Programming the Super User Code (cont.):
2. To toggle operation of the output ON or OFF:
2580 # 7
NOTE:
This function is used to leave the output active for extended periods of time.
While the output remains active, the green LED remains lit.
Do not forget to deactivate this function after its use is no longer required.
It is recommended to only use this function with fail-safe locks. Fail-secure locks may be
damaged by staying activated for too long
3. To temporarily pause or restart the timed output disable period:
2580 # 8
NOTE:
This function is used to enable the operation of the output if it was disabled using the auto-
disable function (see pages 18~19).
When the output auto-disable function is inactive, the red LED will ash steadily. This
indicates that the output may now be used.
4. Disable or enable the output (toggle, regardless of programming):
2580 # 9
NOTE:
This is used to prevent users from accessing the protected premises.
For more information on programming timed or toggle mode, see “Programming the Output
Mode and Output Timing” on page 16.
The red LED will remain steady on while the output is disabled.
For safety reasons, the egress button works regardless of whether the output is enabled or
disabled via the super user code.
The super user code continues to operate the output even while that output is disabled.