ENFORCER Access Control Keypad
SECO-LARM U.S.A., Inc.
Programming the Super User Code (cont.):
2. To toggle operation of the output ON or OFF:
2580 # 7
NOTE:
• This function is used to leave the output active for extended periods of time.
• While the output remains active, the green LED remains lit.
• Do not forget to deactivate this function after its use is no longer required.
• It is recommended to only use this function with fail-safe locks. Fail-secure locks may be
damaged by staying activated for too long
3. To temporarily pause or restart the timed output disable period:
2580 # 8
NOTE:
• This function is used to enable the operation of the output if it was disabled using the auto-
disable function (see pages 18~19).
• When the output auto-disable function is inactive, the red LED will ash steadily. This
indicates that the output may now be used.
4. Disable or enable the output (toggle, regardless of programming):
2580 # 9
NOTE:
• This is used to prevent users from accessing the protected premises.
• For more information on programming timed or toggle mode, see “Programming the Output
Mode and Output Timing” on page 16.
• The red LED will remain steady on while the output is disabled.
• For safety reasons, the egress button works regardless of whether the output is enabled or
disabled via the super user code.
• The super user code continues to operate the output even while that output is disabled.