Cut IN (PSIG) Cut OUT (PSIG)
High pressure switch, AC, WC, RC 350 450
Low pressure switch, AC or WC 30 15
Low pressure pump down (remote) 30 15
Model Series Voltage Brand Amps
N0422, F0522 A or D 115 Tecumseh 5.9-6.1
N0622, F0822 A 115 Tecumseh 5.9-6.1
N0622, F0822 A 230 Tecumseh
N0622, F0822 B or D 115 Copeland 7.1-7.4
N0622, F0822 B or D 230 Copeland
N0922, F1222 A 230 single phase Tecumseh 4.7-5.1
N0922, F1222 A 230 three phase Copeland 3.9-4.1
N0922, F1222 B or D 230 single phase Copeland 4.4 - 5
N0922, F1222 B or D 230 three phase Copeland 3.6-3.8
N1322, F1522 A or D 230 single phase Copeland 6.9-7.2
N1322, F1522 A or D 230 three phase Copeland
Model Ice Machine Voltage Auger Motor Amps Control Cut Out
Amps
N0422 or F0522 115 3.4 - 4 6
N0622 or F0822 115 3.4 - 4 6
N0622 or F0822 230 1.1 - 2 3
N0922 or F1222 230 single or three phase 1.1 - 2 3
N1322 or F1522 230 single or three phase 1.1 - 2 3
Components
Motor: 115 volt or 230 volt versions. 1/4 HP split phase.
Gear Case: Aluminum die cast, service part has no bearings
First gear: Phenolic for noise suppression. Pressed on ball bearing.
Second gear: Steel. Pressed on ball bearing.
Output gear: Steel, pressed shaft and bearings. Supplied with gear case cover.
Output shaft. Provides engagement to auger, uses centering pin for auger alignment. Supplied with gear
case cover.
Input or motor shaft seal. Labyrinth type with o-ring to seal rotor bearing to cover.
Output shaft seal. Lip seal, supplied with gear case cover.
Technical Information
Pressure Switches
Compressor Amp Draw
Auger Drive Motor Amps