Datasheet

6
3-Phase AC Filters / DC Filters
FMBD NEO
https://www.schurter.com /PG80
EMC Products
Derating Curves
Permissible Working Current as a Function of Ambient Temperature
Admissible operating current in %
of In
100
80
60
40
20
0
0 20 40 60 75 100
UL Listed
Ambient air temperature Ta °C
Attenuation Loss
. . . . . 0.1/100 differential mode ........... 100/0.1 differential mode - - - - 50 differential mode _____ 50 common mode
Industrial version
8 A 16A 25A 36A
64A 80A 120A 160A
200A
All Variants
Rated Current @ Ta
50°C (75°C) [A]
Tripped Power Dissipa-
tion [W]
Contact Resistance
[m]
Leakage Cur
-
rent [mA] @ 440V,
60Hz 1)
Weight
[kg]
Screw
clamps
[mm2] 2)
Housings Packaging
unit [PCS]
Order Number
8 (5) 3.2 12.5 11.1 1.1 kg 4 2A 2 FMBD-B92A-0812
16 (11) 7 6.8 11.1 1.2 kg 4 2A 2 FMBD-B92A-1612
25 (16) 9.5 3.8 12.7 1.8 kg 10 2B 2 FMBD-B92B-2512
36 (21) 12.5 2.4 12.7 2 kg 10 2B 2 FMBD-B92B-3612
64 (40) 21.3 1.3 12.7 2.8 kg 25 2C 1 FMBD-B92C-6412
80 (50) 22.6 0.88 13.2 5.7 kg 50 2D 1 FMBD-B92D-8012
120 (96) 43.2 0.75 13.6 6.3 kg 50 2E 1 FMBD-B92E-J212
160 (100) 37.9 0.37 13.6 8 kg 95 2F 1 FMBD-B92F-J612
200 (140) 41.6 0.26 13.6 8.6 kg 95 2F 1 FMBD-B92F-K012
Most Popular.
Availability for all products can be searched real-time:https://www.schurter.com/en/Stock-Check/Stock-Check-SCHURTER