Datasheet

Table Of Contents
8
Power Entry Modules with Line Filter
DG12
https://www.schurter.com /PG06
EMC Products
Type Con guration Code TA35
DG12 - CBDWM100C0-000-C6135 - X X X - X X X X - 0 0
Con guration Code
Panel Mounting 1)
00 Screw version A front mounting
01 Screw version B front mounting
10 Snap-in 1.0 mm
12 Snap-in 1.2 mm
15 Snap-in 1.5 mm
20 Snap-in 2.0 mm
25 Snap-in 2.5 mm
30 Snap-in 3.0 mm
88 Screw version front mounting
(sealed towards housing, IP67)
Color
0 Black
1 White 3)
Screw version A Screw version B
Terminal PE
0 Without (PCII)
1 QC 6.3x0.8 mm
Type of mains  lter (rated current) 2)
1 1A
2 2A
3 3A
4 4A
5 6A
6 8A
7 10A
8 15A (UL), 10A (IEC), 10A (GB)
Type of mains  lter (inductance)
0 standard inductance
1 higher inductance
Type of mains  lter (capacitor)
1 standard X2=100nF, Y2=2200pF
2 standard X2=220nF, Y2=2200pF
3 standard X1=47nF, Y1=2200pF
4 medical M5 X2=100nF
5 medical M5 X2=220nF
6 medical M5 X1=47nF
7 medical M80 X2=100nF, Y2=470pF
8 medical M80 X2=220nF, Y2=470pF
9 medical M80 X1=47nF, Y1=470pF
Con guration Code TA35 2)
See confi guration code of TA35 rocker 2pole
1)
2) The rated current of the line-fi lter must not be
exceeded in the end application.
3) Only on request (approvals pending)
Customer speci c type