User Manual

SCHURTER GmbH
D 79346 Endingen
www.schurter.com
Changes that contribute to technical improvement are subject to alternations.
Page
Date of issue
Author:
Date of change:
Changed by:
Change No.
Datasheet No.
Index
5 of 24
19.05.2008
SHO
26.07.11
SHO
10381
105.9524.200
e
Print date: 26/07/2011 11:54:00
2 TECHNICAL DATA AND DIMENSIONAL DRAWINGS
2.1 Technical Data
Switching Voltage max.
(VAC/DC)
42/60
Switching Current max.
(mA)
100
Rated Breaking Capacity
(W)
1
Lifetime (at Rated Breaking Capacity)
(Mio.)
20
Insulation Resistance (OFF=not actuated)
(MΩ)
>10
Initial Contact Resistance (Ta=25°C) (ON=actuated)
(Ω)
<20
Capacity
(nF)
5
NO Pulse Time
(depending on the actuating force, time and speed)
(ms)
20-1000
Contact Configuration
polarity-free
Switch Function
NO switch
Actuating Force (at ambient temperature)
(N)
≤3
1)
Actuating Travel
(mm)
0.002
Torque
(Nm)
2.5
IK Protection Class
(IK)
02
Operating Temperature
(°C)
-40 to +85
Storage Temperature
(°C)
-40 to +85
IP Degree of Protection Front Side hose water (1m water column)
(IEC/DIN/EN 60529)
(IP)
67
IP Degree of Protection Front Side submerged
(DIN 40050-9:1993 High-pressure cleaning test)
(IP)
69K
Degree of Protection
DIN EN 60069-2-30 Db
(Moist heat (air test with 55°C / 93% humidity)
front side /
rear side
1)
At temperatures lower than -10°C, the actuating force increases 2- to 4-fold.