Datasheet
1 Products affected
Product hierarchy no. *
Part no.
SBU
Type / Description
Customer part no.
SBU
PG
PUG
Type
01
002
022
0000000519
0031.8201
0031.8201.G
Circuit protection
OGN (22.5mm pin space)
n/a
0031.8211
0031.8211.G
OGN (25mm pin space)
n/a
*SBU (2-digit) / PG (3-digit) / PUG (3-digit) / Type (10-digit)
2 Type of change
Modified label
Improved electrical ratings
Change of markings
3 Detailed description of change
The fuseholder OGN has new ratings and approvals as follow:
Old product approval
New product approval
UL 4248-1 - CSA C22.2 no. 4248.1
10A, 500V AC or DC
IEC 60127-6 (VDE)
4W, 10A, 250V AC
UL 4248-1 - CSA C22.2 no. 4248.1
16A, 500V AC or DC
IEC 60127-6:2014 (VDE)
4W, 16A, 500V AC
4W, 10A, 500V AC (with cover)
2.5W, 10A, 500V AC (with transparent cover)
Old label
New label
Old product marking
New product marking
OGN
4W/10A
250V
OGN
4 Reason of change
Product improvement to fulfil the enhanced glow wire requirements according to the updated
standard IEC 60127-6 and the standard IEC 60335-1 for appliances in unattended use.
Recertification and rating enhancement by VDE
Recertification and rating enhancement by UL
1 Products affected
Product hierarchy no. *
Part no.
SBU
Type / Description
Customer part no.
SBU
PG
PUG
Type
01
002
022
0000000519
0031.8201
0031.8201.G
Circuit protection
OGN (22.5mm pin space)
n/a
0031.8211
0031.8211.G
OGN (25mm pin space)
n/a
*SBU (2-digit) / PG (3-digit) / PUG (3-digit) / Type (10-digit)
2 Type of change
Modified label
Improved electrical ratings
Change of markings
3 Detailed description of change
The fuseholder OGN has new ratings and approvals as follow:
Old product approval
New product approval
UL 4248-1 - CSA C22.2 no. 4248.1
10A, 500V AC or DC
IEC 60127-6 (VDE)
4W, 10A, 250V AC
UL 4248-1 - CSA C22.2 no. 4248.1
16A, 500V AC or DC
IEC 60127-6:2014 (VDE)
4W, 16A, 500V AC
4W, 10A, 500V AC (with cover)
2.5W, 10A, 500V AC (with transparent cover)
Old label
New label
Old product marking
New product marking
OGN
4W/10A
250V
OGN
4 Reason of change
Product improvement to fulfil the enhanced glow wire requirements according to the updated
standard IEC 60127-6 and the standard IEC 60335-1 for appliances in unattended use.
Recertification and rating enhancement by VDE
Recertification and rating enhancement by UL
owner
dislercy
creation date
2016-08-11
release date
2017-01-31
released by
nowakfr
change order no
2011797
rev
A
page
1 of 2
D10-007-255
Product Change Notification OGN new approval