Installation Instructions

INSTALLATION INSTRUCTIONS
SQR62101WHZ
ZWAVE PLUG-IN OUTLET
ENERGY MONITORING
15A 125VAC, WHITE
FCC ID: 2AUCU-62101Z
IC: 25381-62101Z
CAN ICES-3(B)/NMB-3(B)
-01-
-02-
-03-
SPECIFICATIONS
Regular Outlet
Voltage ..................................................................................................... 125VAC, 60Hz
Current………………………………………………………………………………………….15A
Controlled Outlet
Voltage………………………………………………………………………………125VAC, 60Hz
Incandescent ........................................................................................................... 1000W
LED ................................................................................................................................. 5A
Standard Ballast ..................................................................................................... 1200VA
Resistive ......................................................................................................... 1800W(15A)
Motor ..................................................................................................................... 1/2 HP
Operating Temperature .............................................................. 32°F104°F(0°C~40°C)
Wireless Type…………………………………………………………………………….. Z-wave
Wireless
Frequency………………………….…………………………908.40MHz/908.42MHz/916MHz
Wireless Range………………………………………….80 feet in open air and line of sight
INSTALLATION
OPERATIONS
WARNING: CALIFORNIA PROPOSITION 65
This product can expose you to chemicals including Carbon black, which is known to the State of
California to cause cancer, and Bisphenol A (BPA),which is known to the State of California to
cause birth defects or other reproductive harm. For more information go to
www.P65Warnings.ca.gov
WARNING
Be sure to read the instruction carefully before installation, and the manufacturer
will not be responsible for any product damage that does not follow the
instruction
1. Wet hands are strictly prohibited.
2. Must work strictly according to the rated load.
3. Do not continue to work after self-disassembly of any nature and damage of
external forces.
4. Don’t touch metal pins during plug in or out.
5. Indoor use only
3. Remote control
Z-Wave remotes can provide control of an Individual device, Groups of devices and Scenes,
depends on the flexibility in how you set up your lighting control network. Please refer to your
gateway’s instruction for details.
Notices for wireless range:
The wireless range is the effective distance of remote control, and it will be impacted by following
conditions.
Each wall or obstacle (i.e. refrigerator, big screen TV, etc.) between the remote or Z-
Wave device and the destination device will reduce the wireless range.
Brick, tile or concrete walls block more of the wireless signal than walls made of wooden
studs and plasterboard (drywall).
The direction angle between remote or Z-wave device and the destination device will also
impact the wireless range, normally put the Z-wave devices face to face will get the best
wireless range.
Wall mounted Z-Wave devices installed in metal junction boxes may suffer a significant loss
of range since the metal box blocks a large part of the wireless signal.
4. Reset to factory defaults
Press the program button and hold for more than 10 seconds.
ADVANCED SETTING
The following Advanced setting requires an advanced gateway. Basic gateway does not
support his setting. Users can do the setting through the interface of the advanced
gateway.
All Configuration Parameters can all be restored to their factory default settings by the gateway or
by manual reset.
Configuration
Parameter
No.
Size
Description
Valid Value
Default
Value
1
1 Byte
Synchronization of outlet
power and LED indicator
0: Power on, LED off
Default=0
1: Power on, LED on
Association
Grouping ID
Max number of nodes
Description
1
1
Lifeline: Send device reset locally notification
2
5
StatusReport: Send basic report
3
5
PowerReport: Send meter power report
LED INDICATION
Blue LED flashing: Connecting to the network.
Blue LED On The switch is switched off (default setting, can be
configured)
Blue LED Off The switch is switched on (default setting, can be
configured).
1. Local control
Press the program button, the appliance or device plugged into Z-Wave
controlled outlet will turn ON or OFF.
Notice: After a power failure, the z-wave controlled outlet returns to OFF state.
2. Join/Leave Z-Wave network.
When the gateway is in adding mode or removing mode, press and hold the program button
for more than 3 seconds.
Notice: Please also refer to the instruction of the z-wave gateway for the operations on gateway
itself.