Datasheet
Multi-stage General Purpose EMI Filter
Approvalsn Rated currents from 1 to 30A
n High differential and common-mode
attenuation
n Optional medical versions (B type)
n Optional safety versions (A type)
Typical applications
n FN 2060 two-stage filters are designed for
easy and fast chassis mounting.
n FN 2060 filters are also available as B
versions without Y-capacitors for medical
applications as well as A version with low
capacitance for safety critical applications
with necessity for low leakage currents.
n All filters provide a high conducted
attenuation performance, based on chokes
with high saturation resistance and
excellent thermal behavior.
n FN 2060 two-stage filters are designed for
noisy applications requiering good
differential and common-mode attenuation.
n FN 2060 filters are also available as single-
stage filters (FN 2010 series).
n Various terminal options allow you to
select the desired connection style.
n Electrical and electronic equipment
n Consumer goods
n Household equipment
n Building automation
n Industrial applications
n Machinery
n Medical equipment
n Electronic data processing equipment
n Office automation and datacom equipment
n Various noisy applications requiering good
filter performance
Features and benefits
Technical specifications
Maximum continuous operating voltage: 250VAC, 50/60Hz
Operating frequency: dc to 400Hz
Rated currents: 1 to 30A @ 40°C max.
High potential test voltage: P –> PE 2000VAC for 2 sec
P –> PE 2500VAC for 2 sec (B types)
P –> N 1100VDC for 2 sec
Temperature range (operation and storage): -25°C to +100°C (25/100/21)
Flammability corresponding to: UL 94V-2 or better
Design corresponding to: UL 1283, CSA 22.2 No. 8 1986, IEC/EN 60939
MTBF @ 40°C/230V (Mil-HB-217F): 950,000 hours
1,650,000 hours (B types)
Typical electrical schematic
P
N
PE
Line
Cx RL L
P‘
N‘
Load
Cx
CyCy
1-phase Filters
FN 2060