User Manual

00:23-03 en-GB 18
©
Scania CV AB 2016, Sweden
Air cleaners
Air cleaners
Reading the air cleaner vacu-
um indicator
If the indicator's red plunger is fully visible, re-
new the air cleaner filter element following the
instructions below.
Renewing the air cleaner filter
element
This procedure applies if the engine has an air
cleaner with a filter element from Scania.
WARNING!
Never start the engine without the air filter as this
could cause injury and severe engine damage.
Note:
Renew the filter element earlier than the mainte-
nance interval if the indicator shows red.
There is always a risk that the filter element will
be damaged when it is cleaned.
The filter element must not be cleaned in water
or be blown clean with compressed air.
1. Remove the cover from the air cleaner.
2. Renew the filter element.
3. Carry out a check by inserting an inspection
lamp into the element and checking from the
outside that there are no holes or cracks in the
filter paper.
4. Assemble the air cleaner.
5. Reset the vacuum indicator by pressing the
button.
A B
336 100
A Vacuum indicator.
B Filter element.
326 671