Installation Sheet

5
6. INSTALLATION OF
SAFETY SUPPORT
An additional safety support is provided to
prevent the fan from falling. Secure the
safety cable to the ceiling joist with screw
and washer, as illustrated in Figure 9.
Hanger bracket
Safety cable
Figure 9
7. MAKE THE ELECTRICAL
CONNECTIONS
WARNING: To avoid possible electrical
shock, be sure electricity is turned off at
the main fuse box before wiring.
Step 1. Motor to House Supply Wires
Electrical Connections: Connect the WHITE
wire (Neutral) from the outlet box to the
WHITE wire marked "AC in N" from the
motor. (Fig. 10)
Step 2. Connect the BLACK wire (Hot) from
the outlet box to the BLACK wire marked
"AC in L" from the motor. (Fig. 10)
Step 3. (Figure 10) If your outlet box has a
ground wire (green or bare copper)
connect it to the fan ground wires;
otherwise connect the hanging bracket
ground wire to the mounting bracket.
Secure the wire connection with a plastic
nut provided. After connecting the wires,
spread them apart so that the green and
white wires are on one side of the outlet
box and black and blue wires are on the
other side. Carefully tuck the wire
connections up into the outlet box.
Note: Fan must be installed at a maximum
distance of 30 feet from the transmitting
unit for proper signal transmission
between the transmitting unit and the
fan's receiving unit.
Figure 10
Outlet Box
Black ("AC IN L")
White ("AC IN N")
White (Neutral)
Black (Hot)
Green or bare
copper (ground)
Ground (green)
(Connect to ground
wire on hanger
bracket if no house
ground wire exists.)