Specifications

SATEL INTEGRA Plus 53
Partitions – indicate the partitions/partition keypads. The output will be controlled by events
related to these partitions/partition keypads.
Timers – indicate the timers which will control the output.
Master users / users – indicate the masters/users. The output will be controlled by events
related to these masters/users.
Outputs – indicate the output. The output will be controlled by events related to these
outputs.
Expanders – indicate the expanders. The output will be controlled by events related to these
expanders.
Troubles – indicate the troubles. The output will be activated by occurrence of these
troubles.
Voice mess. – indicate the synthesizers. The output will be active when the voice messages
with indicated numbers are played back.
Remote switches – indicate the remote switches. The users will control the output by
controlling the selected switches via the telephone.
Burglary zones in partition – indicate the partition in which the output will be activated by
starting the test of burglary zones.
Fire/technical zones in partition – indicate the partition in which the output will be activated
by starting the test of fire or technical zones.
Arm mode – indicate the arm mode whose activation will activate the output.
Telephone usage type – indicate which cases of using the telephone communication by the
alarm control panel will activate the output.
4.5 Clearing alarm in partitions
Indicate the partitions in which alarm clearing will be available (the users having access to
these partitions will be able to clear the alarm).
The alarm must be signaled in the partition where it is to be cleared. If no alarm is
being signaled by the given partition, it will be impossible to clear it.
4.6 Output disabling
Disabling timers – for the 105. S
HUTTER UP
and 106. S
HUTTER DOWN
type outputs, you can
indicate the timers which will block the output. When the timer is active, it is not possible to
control the output.
Partitions – for the 11. C
HIME
type output, you can indicate the partitions from which the user
will be able to block the output using the O
UTPUTS CHIME
function.
4.7 120. Thermostat output parameters
Temperature detector – indicate the zones to which the ATD-100 detectors are assigned.
Temperature T1 – the first temperature threshold. It is active when all control timers are OFF
or the forcing output is active. If the temperature threshold is active, the output will be
turned on if the temperature drops below the threshold.
Temperature T2 – the second temperature threshold. It is active when the control timer is
ON or the forcing output is inactive. If the temperature threshold is active, the output will be
turned on if the temperature drops below the threshold.
The user can edit the temperature thresholds using the T
EMPERATURES
user function
available in the C
HANGE OPTIONS
submenu.