Maintenance and Cleaning
Thisprojectorusesahigh-pressurelampwhichmustbehandledcarefullyandproperly.
Improperhandlingmayresultinaccidents,injury,orcreateafirehazard.
●Lamplifemaydifferfromlamptolampandaccordingtotheenvironmentofuse.Thereisnoguarantee
ofthesamelifeforeachlamp.Somelampsmayfailorterminatetheirlifeinashorterperiodoftime
thanothersimilarlamps.
●Iftheprojectorindicatesthatthelampshouldbereplaced,i.e.,iftheLAMPREPLACEindicatorlights
up,replacethelampwithanewoneIMMEDIATELYaftertheprojectorhascooleddown.
(FollowcarefullytheinstructionsintheLampReplacementsectionofthismanual.)Continuoususeof
thelampwiththeLAMPREPLACEindicatorlightedmayincreasetheriskoflampexplosion.
●A Lampmay explode asa result ofvibration, shock ordegradation as aresult of hoursof use asits
lifetime draws to an end. Risk of explosion may differ according to the environment or conditions in
whichtheprojectorandlamparebeingused.
IF A LAMP EXPLODES, THE FOLLOWING SAFETY PRECAUTIONS SHOULD BE TAKEN.
If a lamp explodes, disconnect the projector’sAC plug from the AC outlet immediately. Contact an
authorized service station for a checkup of the unit and replacement of the lamp.Additionally, check
carefullytoensurethattherearenobrokenshardsorpiecesofglassaroundtheprojectororcomingout
fromthe cooling aircirculation holes.Anybroken shardsfoundshould becleaned upcarefully.Noone
should check the inside of the projector except those who are authorized trained technicians and who
arefamiliarwithprojectorservice.Inappropriateattemptstoservicetheunitbyanyone,especiallythose
whoarenotappropriatelytrainedtodoso,mayresultinanaccidentorinjurycausedbypiecesofbroken
glass.
LAMP HANDLING PRECAUTIONS
Resetting the Lamp Counter
BesuretoresettheLampcounterafterthelampisreplaced.WhentheLampcounterisreset,theLAMP
REPLACEindicatorstopslightingandtheLampreplacementicondisappears.
Note:
Do not reset the Lamp counter without implementing
lamp replacement. Be sure to reset the Lamp counter
onlyafterreplacingthelamp.
Lamp counter Reset?
appears.
SelectYes,thenanother
confirmationboxappears.
SelectYesagaintoreset
theFiltercounter.
PresstheMENUbuttontodisplaytheOn-Screen
Menu.UsethePoint▲▼buttonstoselectSettingand
thenpressthePoint►ortheSELECTbutton.
UsethePoint▲▼buttonstoselectLamp counter
andthenpresstheSELECTbutton.UsethePoint▲▼
buttonstoselectLamp counter resetandthenpress
SELECTbutton.Lamp counter Reset? appears.
SelectYestocontinue.
1
2
Anotherconfirmationdialogboxappears,selectYesto
resettheFiltercounter.
3