user manual
SHR-2040/2041/2042 USER’S MANUAL
5-21
● Quality
Quality will be determined.
Select the one among Very High/High/Normal/Low.
● Rate
Sets the Rate the number of screen recorded every second.
It you set to 15ips, the system records too many screens per second and play continues
intermittently since recording is more detailed. This is appropriate for concentrated
monitoring zone setup.
In case of NTSC, select the one of 30 ips/ 15 ips/ 10 ips/ 7.5 ips/ 5 ips/ 3 ips/ 1 ips.
In case of PAL, select the one of 25 ips/ 12.5 ips/ 8.33 ips/ 6.25 ips/ 5 ips/ 2.5 ips/ 1 ips.
● The Event Recording setup menu will be activated depending on Video On/Off in
Camera Setup (Menu5-12).
● When the video size in the Camera Setup Menu is set to Half D1 and less than 2
cameras are activated, the frame rate of recording may start from
30ips(NTSC)/25ips(PAL) and when the video size in the recording mode is set to
Half D1 and more than 3 cameras are activated, the frame rate of recording may
start from 15ips(NTSC) / 12.5ips(PAL). CIF supports from 30ips(NTSC) /
25ips(PAL) regardless of the number of activated camera.
● Pre-Event
● Post-Event
Records the situation until Alarm is issued.
Off : No recording
5sec/ 10sec/ 20sec/ 30sec : The recording time options before Alarm issue
Records the situation since Alarm is issued.
Off : No recording
5sec/ 10sec/ 20sec/ 30sec/1min/3min/5min/10min/20min: Sets the recording time after an event occurs.
● Video size
The Video size is displayed at the bottom of left 5-19.
Pre-Event Section
Event time
Post-Event Section
Event time
SHR-2040/2041/2042-ENG-1 2005.6.29 4:58 PM Page 5-21