Fixing the Installation Plate
Purging the Unit
Before fixing the installation plate to a wall or window frame, you
must determine the position of the 65 mm hole through which the
cable, piping and hose pass to connect the indoor unit up to the
outdoor unit. When facing the air conditioner in position on the wall,
the piping and cable can be connected from the:
Right
Left
Rear (right or left)
1 Determine the position of the pipe and drain hose hole using the right
figure and drill the hole with an inner diameter of 65 mm so that it slants
slightly downwards.
2 If you are fixing the indoor unit to a... Then follow Steps...
Wall 3.
Window frame 4 to 6.
3 Fix the installation plate to the wall in a manner appropriate to the weight
of the indoor unit.
If you are mounting the plate on a concrete wall with anchor
bolts, the anchor bolts must not project by more than 20 mm.
4 Determine the positions of the wooden uprights to be attached to the
window frame.
5 Attach the wooden uprights to the window frame in a manner appropriate
to the weight of the indoor unit.
6 Using tapped screws, attach the installation plate to the wooden uprights,
as illustrated in the last figure opposite.
INSTALLING THE UNIT
mm03
Installation plate
Pipe hole
(
Ø
65mm)
On delivery, the indoor unit is loaded with an inert gas. All this gas
must therefore be purged before connecting the assembly piping.
To purge the inert gas, proceed as follows.
Unscrew the caps at the end of each pipe.
Result: All inert gas escapes from the indoor unit.
To prevent dirt or foreign objects from getting into the pipes
during installation, do NOT remove the caps completely until
you are ready to connect the piping.
90
90
(Unit : mm)