Product specifications
Features & Operation
33
When you set the sleep mode, the following
movement will start to avoid overcooling.
◆ The indoor fan speed is fixed by setting the
remote controller.
◆ The setting temperature will rise by 1˚C at the
starting of operation and by 1˚C one hour later.
◆ The operation will stop after 6 hours.
3-4. Sleeping Operation
If turbo operation is selected during heating or cooling mode, compressor is operated
for 30 minutes regardless of room temperature. After 30minutes of turbo operation unit will
operate in normal state.
3-5. Turbo Operation(Cooling or Heating Mode)
Start
Stop
1°C up
1˚C up
1h
1h
Ts
Ts+1
Ts+2
Ts+3
6h
AT COOLING MODE
When you set the sleep mode, the following
movement will start to avoid overheating.
◆ The indoor fan speed is fixed by setting the
remote controller.
◆ The setting temperature will be dropped by 1˚C at
the starting of operation and by 1˚C one hour
later.
◆ The operation will stop after 6 hours.
Start Stop
AT HEATING MODE
6hr
1˚C down
1˚C down
Ts+2
Ts+1
Ts+3
Ts+4
Ts+3
Ts+5
1h
1h
00210A(1)-1~83 5/30/01 11:02 AM Page 33