Users Manual Part 1

Phoenix G2 IDU User Manual INSTALLATION
SAF Tehnika JSC
47
Figure 2.6 PhoeniX G2 IDU-ODU cable
DC power cable:
Due to low power consumption of the PhoeniX G2 split mount system, there are no special
requirements for the cable used to connect the IDU to the DC power source. Any 2 wire power
cable of good quality which fits well in SAF Tehnika’s supplied single block 4 pole “screw on”
power connector could be used. The power connector is 2 pole, type 2ESDV-04P.
USB B Serial Connection:
USB B management port must be used for management access with alternative IP address.
This requires USB cable (USB A connector computer side / USB mini B connector IDU
side).
Figure 2.7 PhoeniX G2 USB management cable
RSSI BNC cable:
To connect the digital multimeter to the PhoeniX G2 ODU RSSI port in order to adjust the
antenna alignment, a coaxial cable with BNC connector on one end and appropriate
termination on other end can be used.
Figure 2.8 Cable for connecting the multimeter to the PhoeniX G2 ODU RSSI port