Owner`s manual
chain that is beside it. Let the chain down on the same side of the inner heat shield as the existing one and
attach it to the lever on the damper motor with another pendant. Push the pendant snug into the hole in the
lever. Then mount the controls to the bracket.
4. Adjust the chain on the draft control lever until it is just snug and the damper is still closed. When the damper
motor is energized, the damper should open all the way. Lock the chain into the keyhole with another pendant,
just like the chain beside it.
5. Wire the thermostat as shown in (Figure 16), making sure the wall control is sufficiently away from direct heat
radiation of the fireplace. Make certain to place it at least 10 feet away from the fireplace, but in the same room.
CIRCULATING BLOWER (FDHB5)
NOTE: It is important that the wiring for the blower kit is installed during framing so that the wiring can be easily
hidden.
1. Remove the bottom louver. (See operation #1 in the above section). Pull the louver from the right hand side
toward you. Lift the louver to remove the bottom of the hinge rod from its hole. Remove the top of the hinge
rod from the top hole.
2. Remove the ash pan. To accomplish this you will need to remove the plug from the inside of the firebox.
3. Remove the ash pan drawer. Remove the screw located on the rear right hand side of the drawer at its back.
4. Mount the blower on its 90ยบ bracket. Make sure that the wires are connected to the blower before mounting
5. Hold the blower with the outlet facing up from the back. Fit the blower through the louver opening.
ONYX AP Owner's Manual
RSF Woodburning Fireplaces
18
Figure 17: Circulating blower
Blower speed control
Thermal switch bypass
Thermodisc
Circulating blower
Terminal block
Terminal switch
Mounting clips
Thermal switch
Circulating blower
Bottom louver
Louver retention
Figure 18: Thermal switch location