Specification

HEAT EXCHANGER DESIGN
• Aluminized steel primary heat exchanger with crimped non-
welded construction
• AL29-4C Stainless steel secondary heat exchanger
• Non-welded crimped S-curve primary heat exchanger design
for maximum durability
BURNERS
• Aluminized steel in shot burners for smooth ignition
• Isolated burner enclosure for quiet operation
CABINET CONSTRUCTION
• Compact 33" height
• Standardized widths for easy coil fit
• Unitized construction for cabinet integrity
• Heat exchanger compartment is insulated to increase
efficiency and reduce sound levels
• Baked on pre painted steel cabinet finish
AIR DELIVERY SYSTEM
• Efficient ECM variable speed blower motor
• Motor features "soft start" and "soft stop" for quiet operation
• Active and passive dehumidification feature
• Easily removable slide-out blower design
• Dynamically balanced blower wheel with resilient
motor mounts for smooth and quiet operation
CONTROLS
• Two stage gas valve
• Integrated ignition and fan control
• System Sentry™ control retains last five (5) fault codes with
push button memory recall, regardless of power interruption
• Hot surface ignition system uses silicon nitride ignitor
• Control features 120 volt electronic air cleaner and humidifier
terminals
• Control circuit is fuse protected
• Color coded control wiring
• Compatible with single or two stage thermostats for heating.
• Two stage thermostat is recommended when installed with
two stage cooling unit.
WARRANTY
10 year limited parts warranty / lifetime heat exchanger warranty
available. See limited warranty document for details.
California Only
If installed in South Coast Air Quality Management District (SCAQMD) only: This
furnace does not meet the SCAQMD Rule 1111 NOx emission limit (14 ng/J), and
thus is subject to a mitigation fee of up to $450. This furnace is not eligible for the
Clean Air Furnace Rebate Program: www.CleanAirFurnaceRebate.com.
If installed in San Joaquin Valley Air Pollution Control District (SJVAPCD) only:
This furnace does not meet the SJVAPCD Rule 4905 NOx emission limit (14 ng/J),
and thus is subject to a mitigation fee of up to $450.
CONFIGURATIONS
• Upflow / Horizontal
• Downflow
VENTING
• 2-speed induced draft motor with stainless steel shaft, steel ball
bearings, and fan cooled for long life
• Vent materials for Canadian applications must comply with ULC S636
• Certified for direct vent (2-pipe) or non-direct (1-pipe) applications
• Direct vent refers to a combustion air supply intake pipe installed in
conjunction with flue gas vent pipe.
INSTALLATION FEATURES
• Left or right gas and electric entry
• Zero step horizontal conversion
• Removable floor base (upflow/horizontal units) for bottom return air
• All models comply with California's South Coast Air Quality
Management district Low NOx requirements
96G2V
PRODUCT SPECIFICATIONS
TWO STAGE VARIABLE SPEED
GAS FURNACE
FORM NO. 96G2V-100 (08/2019)
Page 1