Programming Manual
Table Of Contents
- 1. Introduction
- 2. Technical Specifications
- 3. Installation
- 4. Operation
- 5. Programming
- 5.1 Entering the Programming Mode
- 5.2 Exiting the Programming Mode
- 5.3 Changing the Open Code
- 5.4 Changing the Auxiliary Code
- 5.5 Changing the Programming Code
- 5.6 Changing the Normal/Secure Code
- 5.7 Changing the Normal/Bypass Code
- 5.8 Setting Fail Safe/Secure Operation
- 5.9 Setting Auxiliary Modes
- 5.10 Setting the Lockout Feature
- 5.11 Setting the Backlight Behavior
- 5.12 Enrolling Primary and Secondary Codes
- 5.13 Deleting Primary and Secondary Codes
- 5.14 Relay Codes Assignment
- 5.15 Changing PIN Code Length/Factory Default Settings
- 5.16 Replacing a Programming Code
- 5.17 Replacing a Normal/Secure Code
- A. Declaration of Conformity
- B. Limited Warranty
Installation
18 AC-F/G4x Series Installation and Programming Manual
3.2
Wiring
The unit is supplied with a 10-conductor 100-cm (40-in.) pigtail
(18-AWG cable) with exposed wires coated with solder.
To wire the controller:
1. Select the appropriate connections according to Table 1.
Table 1: Wiring Color Guide
Color
Description
Red V input
Black Ground
Green REX/BL
White In / Monitor
Purple Lock: Com
Gray Lock: N.O.
Brown Lock: N.C.
Blue Aux: Com
Yellow Aux: N.O.
Orange Aux: N.C.
2. Prepare the secured power supply’s cable by cutting the
cable jacket back 3.2 cm (1¼”) and strip the wire 1.3 cm
(½”).