Instructions

Table Of Contents
Fernsteuerbefehle
R&S
®
Scope Rider RTH
460Bedienhandbuch 1326.1578.03 ─ 10
Parameter:
<TriggerType> STOF | EOF | FTYP | ID | IDDT | ERRC
STOF
Triggers on the stop bit of the sync field.
EOF
Triggers after a wakeup frame.
FTYP
Triggers on a specified frame type (data, remote, error, or over-
load). For data and remote frames, also the identifier format is
considered.
ID
Sets the trigger to a specific identifier or an identifier range. Only
the 6-bit identifier without parity bits is considered, not the pro-
tected identifier.
IDDT
Sets the trigger to a combination of identifier and data condition.
The instrument triggers at the end of the last byte of the speci-
fied data pattern.
ERRC
Identifies various errors in the frame. You can select one or
more error types as the trigger condition.
*RST:
STOF
TRIGger:CAN:FDATa:BRS <BRSBit>
Sets the bit rate switch bit.
Parameter:
<BRSBit> ZERO | ONE | DC
*RST: DC
TRIGger:CAN:FDATa:DPOSition <ByteOffset>
Sets the byte offset, that defines the start position of the data for the data pattern com-
parison.
The setting is available in CAN FD option R&S RTH-K9.
Parameter:
<ByteOffset> Bereich: 0 bis 63
Inkrement: 1
*RST: 0
TRIGger:CAN:FDATa:ESI <ESIBit>
Sets the error state indicator bit.
Protokollanalyse