User Manual

Table Of Contents
3–40 Status Word/Bit Descriptions
Publication
1771-6.5.88 – July 1997
Notes: 1. For [ ] engineering units, see page 3.
2. When using the Inject/Clamp/Eject mode, all pressure readings are system pressure at input 2, except where noted.
Word
Bit Description
SYS15 Status of On-board Command Blocks
The module latches bits individually when it successfully decodes the referenced command block and places new data
into operational memory. The module does not latch any bit associated with an unrecognizable command block.
The module unlatches all bits in this word:
S
on power start-up, or
S
when it receives a new MCC for decode
When this bit
is latched ON:
this on-board block is valid:
B00 MCC
B01 JGC
B02 FCC
B03 SCC
B04 TCC
B05 LPC
B06 CPC The module also unlatches this bit when it successfully decodes a new FCC, SCC, TCC, or LPC.
B07 INC
B08 IPC The module also unlatches this bit when it successfully decodes a new INC.
B09 PKC
B10 HDC
B11 HPC The module also unlatches this bit when it successfully decodes a new PKC or HDC.
B12 PRC
B13 PLC
B14 PPC The module also unlatches this bit when it successfully decodes a new PLC.
B15 PSC
SYS16 Status of On-board Command Block
The module latches bits individually when it successfully decodes the referenced command block and places new data
into operational memory. The module does not latch any bit associated with an unrecognizable command block.
The module unlatches all bits in this word on power start-up or when it receives a new MCC for decoding.
When this bit
is latched ON:
this on-board block is valid:
B00 FOC
B01 SOC
B02 TOC
B03 OSC
B04 OPC The module also unlatches this bit when it successfully decodes a new FOC, SOC, TOC, or OPC.
B05 EAC
When this bit
is latched ON:
this on-board block is valid:
B06 ERC
B07 EPC The module also unlatches this bit when it successfully decodes a new EAC or ERC.
B08 DYC
B09 RLC
B10 CLC
B11 PTC
B12-B15 Open