Owner's manual

No. 18548 Tube Bender
© SPX Corporation • Form No. 104132 • Rev B, 3-20-03
1. Move backplate handle / connecting bar
assembly around curved forming head
until connecting bar stops on holding
bar. Handles should be positioned as
shown in Figure 1.
Figure 3
4. Move backplate handle around forming head until desired
angle is attained as indicated by the alignment of the
calibration marks. See Figure 3.
Figure 1
WARNING: To prevent
personal injury, wear eye
protection that meets ANSI
Z87.1 and OSHA standards.
Backplate
Handle /
Connecting
Bar
Assembly
Holding Bar
Forming
Head
2. Position tubing (sizes 3/16", 1/4", 5/16", or 3/8") in appropriate
sized groove on forming head and holding bar. Tubing will
start bending at the zero calibration point on forming head.
3. Rotate backplate handle until contact is made with tubing,
and the calibration marks align at zero. See Fig. 2.
Figure 2
Backplate
Handle
SPX Corporation
655 Eisenhower Drive
Owatonna, MN 55060-0995
Technical Services: 1-800-822-5561
Fax: 1-800-822-7805
Customer Service: 1-800-533-6127
Fax: 1-800-322-2890
Website: www.robinair.com
Design, specifications, and
materials are subject to
change without notice.

Summary of content (1 pages)