Specifications

31
10. Maintenance and cleaning
DANGER !
Disconnect from the mains before starting any
maintenance work
A soft lint-free cloth moistened with any good glass cleaning uid is recommended for objective lens, under no
circumstances should alcohol or solvents be used!
Never use alcohol or solvents for cleaning lenses in the moving head!
Use wet cloth only.
It is absolutely essential that the xture is kept clean and that dust, dirt and smoke-uid residues must not build
up on or within the xture. Otherwise, the xture‘s light-output will be signicantly reduced. Regular cleaning will
not only ensure the maximum light-output, but will also allow the xture to function reliably throughout its life.
The front lens may require monthly cleaning as smoke-uid tends to building up residues, reducing the light-
output very quickly. The cooling fans should be cleaned according to the situation (at least annually).
The interior of the base should be cleaned at least annually using a vacuum-cleaner or an air-jet.
More complicated maintenance and service operations are only to be carried out by authorized distributors.
Important! Check the air lter periodically and clean before it become
clogged!
Clean the air lter placed in the rear side of the xture head . Use a vacuum cleaner, compressed air or you
can wash them and put back dry.
After replacing the air lters, reset the elapsed time counter in the menu "Information" (Info--->Air Fil--->Ela
T).
10.1 Replacing a fuse
This replacement has to be realized by a qualied person or ROBE service worker only.
Specications are subject to change without notice.
August 29, 2014
1- fastening screws
2- rear cover of the head
3- Air lter
4- Velcro fastener