Version 1.
REDMix 3•192 Table of contents 1. Safety instructions ...................................................................................................................................................... 3 2. Fixture exterior view ................................................................................................................................................... 5 3. Installation .................................................................................................................
REDMix 3•192 FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE POWERING OR INSTALLING YOUR REDMix 3‐192 ! Save it for future reference. This device has left our premises in absolutely perfect condition. In order to maintain this condition and to ensure a safe operation, it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual.
REDMix 3•192 This fixture was designed for indoor use only, do not expose this unit to rain or use near water. When choosing the installation spot, please make sure that the fixture is not exposed to extreme heat, moisture or dust. Air vents and slots in the fixture´s head and base are provided for ventilation, to ensure reliable operation of the device and to protect it from overheating. The openings should never be covered with cloth or other materials, and never must be blocked.
REDMix 3•192 2. Fixture exterior view 1. Lens array 2. Mounting bracket 3. Covers 4. Lens‐array lock 5. Lens‐array Security locks Rear panel of the fixture 1. Power switch 2. DMX input/output (5‐pin XLR) 3. LED display 4. Mains input 5. Mains output 6. DMX input/output (3‐pin XLR) 7. Mode button 8. Enter button 9. Up button 10. Down button 3. Installation 3.1 Mounting the fixture Ensure that the structure (truss) to which you are attaching the fixtures is secure.
REDMix 3•192 The fixture can be rigged in any orientation on a truss without altering its operation characteristics. The hole in the mounting bracket has a diameter of 10 mm. The installation of the fixture has to be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation. For overhead use, always install a safety rope that can hold at least 10 times the weight of the fixture. You must only use safety rope with screw‐on carbine.
REDMix 3•192 The shape (dimensions) of the plastic film depends on its thickness and elasticity. We advice to use 2 shapes of plastic films: Thickness =< 0.5mm Thickness > 0.5 mm Maximum thickness of the film should not exceed 0.8 mm. 3.3 Connection to the mains If it is necessary, install a suitable plug on the power cord, note that the cores in the power cable are colored according to the following table.
REDMix 3•192 3.4 DMX 512 connection The fixture is equipped with both 3‐pin and 5‐pin XLR sockets for DMX input and output. Only use a shielded twisted‐ pair cable designed for RS‐485 and 3‐pin/5‐pin XLR‐ connectors in order to connect the controller with the fixture or one fixture with another.
REDMix 3•192 Caution: It is necessary to insert the XLR termination plugs (with 120 Ohm) into the input of the master fixture and into the output of the last slave on the data link in order to ensure the proper transmission on the data link. 3.6 Standalone operation The fixtures on a data link are not connected to the controller but can execute pre‐set programs which can be different for every fixture. To set the program to be played, see the "Stand‐alone setting" (menu "St.AL.").
REDMix 3•192 4. REDMix 3•192 DMX protocol Version 1.
REDMix 3•192 Mode/Channel 1 2 3 4 5 15 15 ‐ ‐ 19 16 16 17 ‐ 18 17 ‐ 5 6 ‐ ‐ ‐ Function 0 ‐ 255 Blue LEDs ‐ Array 4 Blue LEDs saturation control (0‐100%) proportional 0 ‐ 255 White LEDs ‐ Array 4 White LEDs saturation control (0‐100%) proportional 20 1 2 Type of control Value 0‐7 8 ‐ 15 16 ‐ 23 24 ‐ 31 32 ‐ 39 40 ‐ 47 48 ‐ 55 56 ‐ 63 64 ‐ 71 72 ‐ 79 80 ‐ 87 88 ‐ 95 96 ‐ 103 104 ‐ 111 112 ‐ 119 120 ‐127 128 ‐ 135 136 ‐ 143 144 ‐ 151 152 ‐ 159 160 ‐ 167 168 ‐ 175 176 ‐ 183 184 ‐
REDMix 3•192 Mode/Channel 1 2 3 4 5 19 18 7 ‐ 3 20 19 8 ‐ Type of control Value Function 0 ‐ 255 Dimmer Dimmer intensity from 0% to 100% proportional 0 ‐ 255 Dimmer, fine Fine intensity from low to high proportional 4 12
REDMix 3•192 5. Control menu map Default settings=Bold print Menu Level 1 Menu Level 2 Menu Level 3 A001 dM.Ad. 001‐512 MA.SL. d.AbL Menu Level 4 MASt. SLA InFo Poti. FuLL totL rSEt EcO totL rSEt FiLt. AL.PE. 10......300 EL.ti. DM.In. rEd1 0‐255 : tEMP. F.dim 0‐255 Cur.t. boAr.. LEdS Hi.tE. boAr.. LEdS rSEt boAr.. LEdS VErS. IC1 IC2 PErS dM.Pr. Mod.1 Mod.2 Mod.3 Mod.4 Mod.
REDMix 3•192 Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 dISP. d.On On, Off d.Int. 20...100 turn On, Off tEM.U. °C, °F bALA On, Off C.bAL. rEd 0..200..255 GrEn 0..........255 bLuE 0..237..255 Stor LOAd FuLL EcO In.Po. rEd1 0‐255 : F.dim 0‐255 Stor. dFSE MAn.M. PrE.C. rEd1 rE1.1..rE1.3 : Man.C. dimr dim0...dim.7 rEd1 0‐255 : F.dim 0‐255 TESt St.AL. Auto Off tESt PrG.1 : PrG.
REDMix 3•192 Menu Level 1 Menu Level 2 Menu Level 3 Menu Level 4 Menu Level 5 Menu Level 6 PLAY tESt PrG.1 St.01 rEd1 0‐255 : : : : PrG.3 St.68 S.tim. 0‐25.5 sec PrG.1 : PrG.3 Edit CoPY SPEC. rdML rdMH Adj. DMH rEd1 : F.dimr CaL.U. rEd1 : wh4 Stor. uPd.M. 6. Fixture menu The control panel menu allows to set the fixture according to your needs, obtain information on its operation, test its various parts and lastly program it, if it has to be used in a Stand‐alone mode.
REDMix 3•192 6.1 Fixture Address Use this menu to set the DMX address of the fixture or set the fixture as a Master (Slave). dM.Ad. ‐‐‐ DMX addressing. Select this submenu to set a DMX start address. To set a DMX address. 1. Use the UP/DOWN buttons to find “ A001“ menu. 2. Press the ENTER button. 3. Use the UP/DOWN buttons to select desired start address. 4. Press the ENTER button to confirm the choice. MA.SL. ‐‐‐ Master/slave addressing. Select this submenu to set the fixture as a master or slave.
REDMix 3•192 FiLt ‐‐‐ Filters. Regular cleaning of the air filters is very important for the fixture´s life and performance. Cumulation of dust, dirt and fog fluid residues reduces the fixture´s light output and cooling ability. The two items of this menu help you to keep cleaning period of the air filters. AL.PE. ‐‐‐ Set alert period ‐ cleaning schedule for the fixture depends on the operating environment. It is therefore impossible to specify accurate cleaning interval.
REDMix 3•192 C.bAL. ‐‐‐ White Colour Balance. The menu gives access to the setting of the white balance. To set white colour balance. 1. Use a DMX controller or the “ Man.C.“ menu to set all LEDs on max. saturation. 2. Use the UP/DOWN buttons to find the “ Pers.“ menu. 3. Press the ENTER button. 4. Use the UP/DOWN buttons to select the “C.bAL“menu. 5. Press the ENTER button and the “rEd“ item will appear on the display. 6. Press the ENTER button and use the UP/DOWN buttons to set new max.
REDMix 3•192 6. 5 Test sequences Use this menu to run demo‐test sequences without an external controller, which will show you some possibilities of using the REDMix 3•192. 6.6 Standalone setting The fixtures on a data link are not connected to the controller but can execute pre‐set programs which can be different for every fixture. “Stand‐alone operation” can be applied to the single fixture or to multiple fixtures operating synchronously.
REDMix 3•192 “MACr“ ‐ colour macros (0‐255) “Stro.“ ‐ a strobe, shutter (0‐255) “dimr“ ‐ a dimmer (0‐255) “F.tim.“ ‐ a fade time, (0‐25.5) seconds “S.tim.“ ‐ step time, value (0‐25.5) seconds “COPY“. – this item duplicates the current prog. step to the next prog. step. The item “P.End” is increased automatically. 6. Use the UP/DOWN buttons to set a DMX value of the channel and then press the ENTER button. 7. Use the UP/DOWN buttons to select next channel and press the ENTER button. 8.
REDMix 3•192 4 Press the ENTER button 5 Use the UP/DOWN buttons to select “ yES“ option 6 Press the ENTER button Note: If you do not want to continue in software update, you have to switch off and on the fixture to escape from this menu. 3. We recommend to cancel all running programs before start the Software Uploader. 4. Run the Software Uploader program. Select desired COM and then click on the Connect button. Select COM if the seriál port is used. Select DreamBox1 if the USB port is used.
REDMix 3•192 Parameter ID Discovery command DISC_UNIQUE_BRANCH * DISC_MUTE * DISC_UN_MUTE * SET command DEVICE_INFO Parameter ID GET command * Discovery command SET command GET command SUPPORTED_PARAMETERS * SOFTWARE_VERSION_LABEL * DMX_START_ADDRESS * * IDENTIFY_DEVICE * * DEVICE_MODEL_DESCRIPTION * MANUFACTURER_LABEL * DEVICE_LABEL * * SENSOR_DEFINITION * SENSOR_VALUE * DISPLAY_LEVEL * DEVICE_RESET * DMX_PERSONALITY * * * DMX_PERSONALITY_DESCRIPTION * STATUS_ME
REDMix 3•192 9. Technical specifications Power supply • Electronic auto‐ranging • Input voltage: 100 ‐ 250V AC, 50‐60 Hz • Fuse: T8 A • Max.
REDMix 3•192 Dimensions (mm) Weight • 10 kg Included items • 1 x REDMix 3•192 • 1 x Lens module 25° (No. 99012301) – installed in the fixture • 1 x glass holder for frost filter (No. 10980055) • 1 x grid module (No. 17040456) • 1 x User manual Optional accessories • Lens module 45° (No. 10980053) • Lens module 15°x45° (No. 10980054) • Flash cable RS232/DMX (No.
REDMix 3•192 10. Cleaning and maintenance It is absolutely essential that the fixture is kept clean and that dust, dirt and smoke‐fluid residues must not build up on or within the fixture. Otherwise, the fixture‘s light‐output will be significantly reduced. Regular cleaning will not only ensure the maximum light‐output, but will also allow the fixture to function reliably throughout its life.