Environment
Air surrounding the water heater is used for
combuson and must be free of any compounds that
cause corrosion of internal components. These
include corrosive compounds that are found in
aerosol sprays, detergents, bleaches, cleaning
solvents, oil based paints/ varnishes, and refrigerants.
The air in beauty shops, dry cleaning stores, photo
processing labs, and storage areas for pool supplies
oen contains these compounds. Therefore it is
recommended that such locaons be avoided.
If it is necessary for a water heater to be located in
areas which may contain corrosive compounds, the
following instrucons are strongly recommended.
IMPORTANT CONSIDERATIONS FOR INSTALLATION:
DO NOT Install in areas where air for combuson
can be contaminated with chemicals.
Before installaon, consider where air has the
ability to travel within the building to the water
heater.
Chemicals that are corrosive in nature should not
be stored or used near the water heater.
Damage and repair due to corrosive compounds in
the air is not covered by warranty.
Consideraon of care for your water heater should
include evaluaon of water quality.
Water that contains chemicals exceeding the levels
below aect and damage the heat exchanger.
Replacement of the heat exchanger due to water
quality damage is not covered by the warranty.
Maximum Level
Total Hardness Up to 200 mg / L
Aluminum * Up to 0.2 mg / L
Chlorides * Up to 250 mg / L
Copper * Up to 1.0 mg / L
Iron * Up to 0.3 mg / L
Manganese * Up to 0.05 mg / L
pH * 6.5 to 8.5
TDS (Total Dissolved Solids) * Up to 500 mg / L
Zinc * Up to 5 mg / L
Determine Installaon Locaon
Water Quality
* Source: Part 143 Naonal Secondary Drinking Water
Regulaons
If you install this water heater in an area that is
known to have hard water or that causes scale build-
up the water must be treated and/or the heat
exchanger ushed regularly.
You must ensure that clearances will be met and that
the vent length will be within required limits.
Consider the installaon environment, water quality,
and need for freeze protecon. Requirements for the
gas line, water lines, and electrical connecon can be
found in their respecve installaon secons of this
manual.