A licensed professional must install the appliance,
inspect it, and leak test it before use. The warranty
will be voided due to improper installaon.
The installer should have skills such as:
gas sizing
connecng gas lines, water lines, valves, and
electricity
knowledge of applicable naonal, state, and
local codes
installing venng through a wall or roof
Venng Category I, Fan Assist Appliances per
NFPA54 and local codes
If you lack these skills contact a licensed professional.
Installaon Instrucons
Installaon Steps
Determine Installaon Locaon ................ 8
Installaon Locaon .................................. 9
Checklist to Determine Locaon ............. 10
Minimum Clearances………....................... 11
Typical Installaon Illustraon ................ 12
Combuson Air Requirements ........... 13-15
Venng Requirements ........................ 16-19
Checklist for Combuson Air
and Venng ............................................. 20
Installaon of Plumbing ........................... 21
Checklist for Plumbing ............................. 22
Massachuses-Required Plumbing ......... 23
Installaon of Gas Supply ................... 24-25
Connect Electricity ................................... 26
Adjust for High Altude ........................... 26
Checklist for Gas and Electricity .............. 26
Final Checklist .......................................... 27
General Instrucons Installer Qualicaons
DO NOT
Do not install the RH180 outdoors.
Do not install the appliance in an area where water
leakage of the unit or connecons will result in
damage to the area adjacent to the appliance or to
lower oors of the structure. When such locaons
cannot be avoided, it is recommended that a
suitable drain pan, adequately drained, be installed
under the appliance. The pan must not restrict
combuson air ow.
Do not obstruct the ow of combuson and
venlaon air.
Do not use this appliance in an applicaon such as
a pool or spa heater that uses chemically treated
water . (This appliance is suitable for lling large or
whirlpool spa tubs with potable water.)
Do not use substute parts that are not authorized
for this appliance.
MUST DO
The installaon must conform with local codes or,
in the absence of local codes, with the Naonal
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installaon Code, CSA
B149.1.
The appliance, when installed, must be electrically
grounded in accordance with local codes or, in the
absence of local codes, with the Naonal Electrical
Code, ANSI/NFPA 70, or the Canadian Electrical
Code, CSA C22.1.
The appliance and its appliance main gas valve
must be disconnected from the gas supply piping
system during any pressure tesng of that system
at test pressures in excess of 1/2 psi (3.5 kPa)
(13.84 in W.C.).
The appliance must be isolated from the gas supply
piping system by closing its individual manual
shuto valve during any pressure tesng of the gas
supply piping system at test pressures equal to or
less than 1/2 psi (3.5 kPa) (13.84 in W.C.).