User Guide

10 RH180 Manual
Checklist to Determine Installaon
Locaon
The water heater is not exposed to corrosive
compounds in the air.
The water heater locaon complies with the
clearances stated in the manual and on the label,
located on the side of the unit.
The area surrounding the water heater does not
contain ammable vapors that could ignite.
The water supply does not contain chemicals or
exceed total hardness that will damage the heat
exchanger.
The water heater and its water lines are protected
from freezing.
A standard 3 prong 120 VAC, 60 Hz properly
grounded wall outlet or other properly grounded
120 VAC, 60 Hz source is available.
The installaon must conform with local codes or,
in the absence of local codes, with the Naonal
Fuel Gas Code, ANSI Z223.1/NFPA 54, or the
Natural Gas and Propane Installaon Code, CSA
B149.1.
Leave the enre manual taped to the water
heater or give the enre manual directly to the
consumer.