Regency Horizon™ HZ40E Gas Fireplace Horizon HZ40E Product Video Owners & Installation Manual MODELS: HZ40E-NG2 Natural Gas HZ40E-LP2 Propane www.regency-fire.com WARNING: FOR YOUR SAFETY If the information in these instructions are not followed exactly, What to do if you smell gas: a fire or explosion may result causing property damage, Do not try to light any appliance Do not touch any electrical switch: personal injury or loss of life. do not use any phone in your FOR YOUR SAFETY building.
MANUFACTURED MOBILE HOME REQUIREMENTS INFORMATION FOR MOBILE/MANUFACTURED HOMES AFTER FIRST SALE This Regency® product has been tested and listed by Warnock Hersey/Intertek as a Direct Vent Wall Furnace to the following standards: VENTED GAS FIREPLACE HEATERS ANSI Z21.88-2009 / CSA 2.33-2009 and GAS-FIRED APPLIANCES FOR USE AT HIGH ALTITUDES CAN / CGA 2.17-M91. This appliance may only be installed in an aftermarket permanently located, manufactured (U.S.
To the New Owner: Congratulations! You are the owner of a state-of-the-art Gas Fireplace by REGENCY®. The HZ40E has been designed to provide you with all the warmth and charm of a fireplace at the flick of a switch. The model HZ40E has been approved by Warnock Hersey/Intertek for both safety and efficiency. As it also bears our own mark, it promises to provide you with economy, comfort and security for many trouble free years to follow.
TABLE OF CONTENTS SAFETY DECAL Copy of Safety Decal .....................................................5 REQUIREMENTS MA Code - CO Detector.................................................6 INSTALLATION Important Message ......................................................8 Before You Start ............................................................8 General Safety Information............................................8 Installation Checklist ......................................................
SAFETY LABEL This is a copy of the label that accompanies each HZ40E-NG2 and HZ40E-LP2 Direct Vent Gas Fireplace. We have printed a copy of the contents here for your review. NOTE: Regency® units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
REQUIREMENTS MA Code - CO Detector (for the State of Massachusetts only) 5.08: Modifications to NFPA-54, Chapter 10 (2) Revise 10.8.
DIMENSIONS 49-5/16" 45-5/8" 18-5/16" 39-13/16" 31" 10" 33-3/16" 16-1/2" 16-7/8" 1 36 4 " 42" 1 13 4 " 1-7/16" (1092mm) (972mm) Regency Horizon™ HZ40E-2 Gas Fireplace (914mm) (327mm) (522mm) (600mm) 15 14 (318mm) (902mm) (388mm) (1238mm) 7
INSTALLATION IMPORTANT MESSAGE SAVE THESE INSTRUCTIONS The Gas Fireplace must be installed in accordance with these instructions. Carefully read all the instructions in this manual first. Consult the "authority having jurisdiction" to determine the need for a permit prior to starting the installation. It is the responsibility of the installer to ensure this fireplace is installed in compliance with manufacturers instructions and all applicable codes.
INSTALLATION INSTALLATION CHECKLIST 1) Locate appliance a) Room location (Refer to "Locating Your Gas fireplace" section) b) Clearances to Combustibles (Refer to "Clearances" section) c) Mantel Clearances (Refer to "Mantel Clearances" section) d) Framing & Finishing Requirements (Refer to "Framing & Finishing" section) e) Venting Requirements (Refer to "Venting" section) This includes: 1) Clocking the appliance to ensure the correct firing rate (rate noted on label 26,000 Btu/h (NG), 25,500 Btu/h (LP) afte
INSTALLATION CLEARANCES The clearances listed below are Minimum distances unless otherwise stated: A major cause of chimney related fires is failure to maintain required clearances (air space) to combustible materials. It is of the greatest importance that this fireplace and vent system be installed only in accordance with these instructions. WARNING Caution Requirements The top, back and sides of the fireplace are defined by standoffs.
INSTALLATION MANTEL CLEARANCES Due to the extreme heat this fireplace emits, the mantel clearances are critical. Combustible mantel clearances from top of front facing are shown in the diagram on the right. 14 12 10 8 6 4 2 26 13" (330mm) Combustible Material Note: Ensure the paint that is used on the mantel and the facing is "high quality" or the paint may discolour.
INSTALLATION UNIT ASSEMBLY PRIOR TO INSTALLATION The nailing Strips must be correctly positioned and attached before unit is slid into position. NAILING STRIPS The nailing strips come attached to the unit. There is 1 plate on each side, 1 on the top. There also two on the bottom. The top and side nailing strips are secured to the framing. The bottom nailing strips are IMPORTANT NOTE Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible.
INSTALLATION FRAMING DIMENSIONS Framing Dimensions Description A B Framing Height Framing Width C* Framing Depth* D E F G H I J K Minimum Height to Combustibles Corner Wall Depth Corner Facing Wall Width Vent Centerline Height Non-combustible facing height Gas Connection Opening Height Gas Connection Height Gas Connection Inset L Gas Connection Opening Width HZ40E 42” (1067mm) 49-7/8" (1266mm) C1 Horizontal Vent 19-7/16" (495mm) C2 Vertical Vent 23-7/16" (596mm) Vertical rise -terminating horizont
INSTALLATION WALL MOUNT ON / OFF SWITCH AND BATTERY COMPARTMENT INSTALLATION AND/OR RECEIVER INSTALLATION REQUIRED FOR ALL INSTALLATIONS - INCLUDING PROFLAME REMOTE CONTROLS IMPORTANT INSTALLATION NOTE: The Receiver must be placed inside the supplied (Low Voltage) junction type wall box and installed into the wall only. DO NOT INSTALL WITHIN THE CONFINES OF THE FIREPLACE. Remote Receiver Installation 1. Install the low voltage junction box to the framing, at desired location within 10 ft. from fireplace.
INSTALLATION NON-COMBUSTIBLE REQUIREMENTS * Installation of the Receiver must be completed before installing non-combustible facing. All three pieces (top, 2 sides) are now supplied to meet the non combustible requirements. Previously only the top was supplied. Metal Stud 20" (508mm) 33 -13/16" (859mm) Non-combustible Material Non-combustible Note: Calcium Silicate is 1/2' thick Metal Stud Non-combustible If finishing the wall above the unit with materials such as tile, brick, marble, etc.
INSTALLATION FRAMING & FINISHING 1) Frame in the enclosure for the unit with framing material. IMPORTANT: The framed opening must be of non-combustible material. Note: When constructing the framed opening, please ensure there is access to install the gas lines when the unit is installed.
INSTALLATION FRAMING & FINISHING Finished Material Nailing Strip Position 1/2" 1" Nailing Strip 1” Forward Unit 1" 1/2" Nailing Strip ½” Forward Note: Depending on the material used for finishing, the nailing strips must be set accordingly so that the finished material is always at the 1-1/2" edge of the flange.
INSTALLATION EXTERIOR VENT TERMINATION REQUIREMENTS Minimum Clearance Requirements Canada1 USA2 A Clearance above grade, veranda, porch, deck, or balcony 12"(30cm) 12"(30cm) B Clearance to window or door that may be opened 12"(30cm) 9" (23cm) C Clearance to permanently closed window * * D Vertical clearance to ventilated soffit located above the terminal within a horizontal distance of 2 feet (61cm) from the center line of the terminal (check with the local code) 19"(48cm) 19"(48cm) E C
INSTALLATION 4” X 6-5/8” RIGID PIPE CROSS REFERENCE CHART ONLY Components from different Manufacturers may not be mixed. Not All Rigid Pipe components are available directly from FPI.
INSTALLATION Description Simpson Selkirk Direct Vent Pro® Direct Temp™ American Metal Products® Metal-Fab™ Security ICC Excel Sure Seal Secure- Vent® Direct Amerivent Direct Attic Insulation Shield 12” 46DVA-IS N/A@ FPI N/A 4DAIS12 N/A SV4RSA N/A Attic Insulation Shield - Cold Climates 36” N/A N/A 4DAIS12 N/A N/A TM-4AS Basic Horizontal Termination Kit (A) Disc.
INSTALLATION VENT RESTRICTOR POSITION Vent restriction is required for certain venting installations, see the diagrams in the "Venting Arrangements" section to determine if they are required for your installation. The Vent Restrictor plate is located on the inside top of the firebox. To set the vent restriction as indicated in the venting arrangements diagrams, refer to the following instructions; 1) Remove the glass door - see instructions in this manual.
INSTALLATION VENTING INTRODUCTION The HZ40E uses the "balanced flue" technology Co-Axial system. The inner liner vents products of combustion to the outside while the outer liner draws outside combustion air into the combustion chamber thereby eliminating the need to use heated room air for combustion and losing warm room air up the chimney. Note: These flue pipes must not be connected to any other appliance.
INSTALLATION HORIZONTAL TERMINATIONS FLEX VENT 4" X 6-7/8" These venting systems, in combination with the HZ40E Direct Vent Gas Fireplace, has been tested and listed as a direct vent heater system by Warnock Hersey/ Intertek. The location of the termination cap must conform to the requirements in the Vent Terminal Locations diagram in "Exterior Vent Termination Locations" section. Regency® Direct Vent (Flex) System Termination Kits includes all the parts needed to install the HZ40E using a flexible vent.
INSTALLATION HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The minimum components required for a basic horizontal termination are: 1 1 1 1 1 Horizontal Termination Cap 45o Elbow Rigid Pipe Adaptor (510-994) Wall Thimble Length of pipe to suit wall thickness (see chart) Wall thickness is measured from the back standoffs to the inside mounting surface of termination cap.
INSTALLATION HORIZONTAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The diagrams below shows examples of horizontal termination arrangements using one, two, or three 90o elbows (two 45o elbows equal one 90o elbow) 1) A maximum of three 90o elbows are permitted (not including the starting 45o elbow at the flue collar when using rigid venting). 2) Minimum distance between elbows is 1 ft. (305mm). • • • • • • Maintain clearances to combustibles as listed in the "Clearances" section.
INSTALLATION Horizontal Venting with Two (2) 90o Elbows Horizontal Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. Option V H + H1 A) 1' Min. 3' Max. B) 2' Min. 4' Max. C) 3' Min. 5' Max. D) 4' Min. 6' Max. E) 5' Min. 7' Max. F) 6' Min. 8' Max. One 90o elbow = Two 45o elbows. With these options, maximum total pipe length is 28 feet with minimum of 6 feet total vertical and maximum 8 feet total horizontal. Option H V H+H1+H2 A) 1' Max. 1' Min. 3' Max.
INSTALLATION Horizontal Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. Option V H V+V1 H+H1 A) 2' Min. 1' Max. 3' Min. 4' Max. B) 3' Min. 2' Max. 4' Min. 5' Max. C) 4' Min. 3' Max. 6' Min. 6' Max. D) 5' Min. 4' Max. 8' Min. 7' Max. E) 6' Min. 5' Max. 10' Min. 8' Max. F) 7' Min. 6' Max. 12' Min. 9' Max. With these options, maximum total pipe length is 28 feet with minimum of 12 feet total vertical and maximum 9 feet total horizontal.
INSTALLATION VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" The minimum components required for a basic vertical termination are: 1 1 1 1 1 1 1 Vertical Termination Cap 45o Elbow Rigid Pipe Adaptor (510-994) Ceiling Firestop Flashing Storm Collar Length of pipe to suit wall thickness (see chart) Vertical Terminal Storm Collar Flashing Galvanized pipe is desirable above the roofline due to its higher corrosion resistance.
INSTALLATION VENTING ARRANGEMENT FOR VERTICAL TERMINATIONS Vertical Venting with One(1) 90o Elbows (1 - 90o = 2 - 45o) Horizontal (Feet) The shaded area in the diagram shows all allowable combinations of straight vertical and offset to vertical terminations, using one 90o elbow, with Rigid Pipe Venting Systems. 0 2 4 6 8 10 12 14 16 18 20 40 Two 45o elbows equal to one 90o elbow, not including the starting 45o elbow at the flue collar. Vent must be supported at offsets.
INSTALLATION VERTICAL TERMINATION WITH CO-LINEAR FLEX SYSTEM THE APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING A SEPARATE SOLID FUEL BURNING APPLIANCE. Masonry chimneys may take various contours which the flexible liner will accommodate. However, keep the flexible liner as straight as possible, avoid unnecessary bending. The Air Intake pipe must be attached to the inlet air collar of the termination cap.
INSTALLATION VERTICAL TERMINATIONS RIGID PIPE 4" X 6-5/8" • • • • • • • Two 45o elbows equal to one 90o elbow. Maximum of four 45o elbows allowed, not including the starting 45o elbow at the flue collar. Vent must be supported at offsets. Minimum distance between elbows is 1 ft. (305mm). Maintain clearances to combustibles as listed in the "Clearances" section. Horizontal vent must be supported every 3 feet. Firestops are required at each floor level and whenever passing through a wall.
INSTALLATION Vertical Venting with Three (3) 90o Elbows One 90o elbow = Two 45o elbows. Option A) B) C) D) E) H 1' Max. 2' Max. 3' Max. 4' Max. 5' Max. V 1' Min. 2' Min. 3' Min.' 4' Min. 5' Min. H + H1 3' Max. 4' Max. 5' Max. 6' Max. 7' Max. V + V1 3' Min. 5' Min. 7' Min. 9' Min. 11' Min. With these options, max. total pipe length is 30 feet with min. of 11 feet total vertical and max. 7 feet total horizontal. Please note min. 1 foot between 90 o elbows is required.
INSTALLATION VENTING ARRANGEMENTS - VERTICAL TERMINATIONS with Co-linear Flex System for both Residential & Manufactured Homes into Masonry Fireplaces 35 Horizontal Distance (Feet) Vent Restrictor Set 1 Combined max. of 16' Max. Combined max. of 35' (10.7m) Max. . 36-1/4” 6’ (152mm) max. (921mm) 2’ (51mm) max. Combined min. of 8’ (2.4m). Vent Restrictor Set 2 Restrictor Set 1 Restrictor Set 2 Horizontal Distance (Feet) Vertical Height (feet) 35' (10.7m) Max. 8' (2.4m) Min.
INSTALLATION 4" X 6-5/8" VENTING (Rigid Vent Systems) Minimum Vent Clearances to Combustibles * Clearances noted below must be maintained; except when passing through a wall, ceiling or at the termination where the use of a firestop or wall thimble reduces clearance to 1-1/2" (38mm).
INSTALLATION UNIT INSTALLATION WITH HORIZONTAL TERMINATION NOTE: Horizontal sections must be supported at intervals not exceeding 3 feet (0.9 meter). (Flame picture and performance will be affected by sags in the liner). 4" X 6-5/8" VENTING (Flex Vent Systems) 4) Separate the 2 halves of the wall thimble and securely fasten the one with the tabs to the outside wall making sure that the tabs are on top and bottom. Fasten the other thimble half to the inside wall.
INSTALLATION UNIT INSTALLATION WITH VERTICAL TERMINATION 4) Assemble the desired lengths of pipe and elbows. Ensure that all pipes and elbow connections are in the fully twist-locked position and sealed. 4" X 6-5/8" VENTING (Rigid Vent Systems) Diagram 4 1) Maintain the 1-1/2" clearances (air spaces) to combustibles when passing through ceilings, walls, roofs, enclosures, attic rafter, or other nearby combustible surfaces. Do not pack air spaces with insulation.
INSTALLATION HZ40E-NG2 SYSTEM DATA Min. Supply Pressure 5" WC (1.25 kpa) Manifold Pressure 3.5" WC (0.87 kpa) Orifice Size #40 DMS Maximum Input 26,000 Btu/h (7.61 kW) Minimum Input 18,000 Btu/h (5.28 KW) PILOT ADJUSTMENT Periodically check the pilot flames. Correct flame pattern has two strong blue flames: 1 flowing around the flame sensor and 1 flowing across the burner (it does not have to be touching the burner). Burner Flame Sensor HZ40E-LP2 SYSTEM DATA Min. Supply Pressure 11" WC (2.
INSTALLATION AC POWER ADAPTOR INSTALLATION (FOR SUREFIRE SYSTEMS) An optional AC power adaptor may be installed as a constant power source for the SureFire system. NOTE: AC power adaptor is not required when using GTMF Remote IMPORTANT: Recommend removing the 4-AA batteries in the SureFire receiver. This will avoid battery leakage and power drainage. 4-AA Battery pack may be re-installed into receiver during power outages.
INSTALLATION WIRING DIAGRAM This heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation. (Do not cut the ground terminal off under any circumstances.
INSTALLATION PROFLAME SYSTEM GTMF WITH OPTIONAL FAN Proflame System Configuration 885 GTMF 886 Wire Diagram SureFire™ Switch Ground Fan Fan Neutral 120V AC 60 Hz Live Black Ground Black White Black Green Black Red Fan Thermodisc (normally open) Caution: Ensure that the wires do not touch any hot surfaces and are away from sharp edges. CAUTION: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.
INSTALLATION OPTIONAL FAN WIRING DIAGRAM WITHOUT PROFLAME GTMF SYSTEM Lockwasher Star washer Ground #8 Ground Lug (for mobile home) Fan Fan Neutral 120V AC 60 Hz Live White Black Ground Black Green Black Black Nut Fan ground wire Red Fan Thermodisc (normally open) Electrical Connection Alternative Scheme "A", Power at Stove Wall Junction Box ~ Wire Nuts Electrical Connection Alternative Scheme "B", Power at Switch Wall Junction Box *Speed Control Switch with lead wires (Regency) ~ *Speed
INSTALLATION Optional REMOTE CONTROL Use the Regency® Remote Control approved for this unit. Use of other systems may void your warranty. The remote control comes with a hand held transmitter. *Proflame GT remote control 946-700 RF remote, ON/OFF Thermostat, ON/OFF Flame Control Large blue backlit LCD screen with temperature display receiver.
INSTALLATION GTMF REMOTE INSTALLATION 120 Volt AC power is needed for the fan. The fan can be hard wired if desired. The receptacle box should be installed on the right hand side of the unit by a qualified electrician. The neutral (wider) slot of the polarized receptacle should be at the top. Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances. INTO EXISTING INSTALLATIONS 1) Shut off the gas and power supply to the unit.
INSTALLATION 5) Loosen 2 screws at the back of the burner to release it. 8) Once the top panel is removed - the left side panel will be accessible. Remove 3 screws from the left side access panel in locations shown below. Note: Some components have been removed for illustration purposes. 6) Remove the burner by sliding it to the right - then lift out. 9) Install the fan control module (FCM) through the opening created by the removed left side access panel.
INSTALLATION 11) Locate the digital firebox control box. 12) Plug the fan power cord into the fan control module in the outlet marked fan. Plug in the FCM wire (from the digital firebox control box wire harness) into the location on the fan control module marked com FCM Wire Com 13) See Proflame remote instructions for coding remote to receiver as well as operating instructions. 14) Reverse steps 2-1 for new installations. Reverse steps 8 - 1 for existing installations.
INSTALLATION OPTIONAL FAN INSTALLATION 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualified electrician. The neutral (wider) slot of the polarized receptacle should be at the top see page 41 for wiring diagram). Unit must be grounded at all times. Do not cut the ground terminal off under any circumstances.
INSTALLATION OPTIONAL FAN INSTALLATION - INTO EXISTING INSTALLATIONS 120 Volt AC power is needed for the fan switch and blower. The fan can be hard wired if desired. The receptacle box should be installed on the left hand side of the unit by a qualified electrician. The neutral (wider) slot of the polarized receptacle should be at the top (see page 41 for wiring diagram). 7) Loosen 3 screws at the back of the burner to release it. Unit must be grounded at all times.
INSTALLATION 10) Maneouver fan through left access panel opening. 11) To complete fan installation - follow steps 2- 7 on previous page. NOTE: The right access panel wasremoved to allow easier access to secure the right screw on the fan base. 12) Reverse steps 9-1 to complete install.
INSTALLATION INNER PANEL INSTALLATION 7) Install the left side enamel panel - secure in position with the panel clip and two tighten two screws loosened in step 2, as shown in the diagram below. Handling Instructions Black Enamel Panels • Black Enamel panels must be inspected for scratches and dimples prior to installation. All claims to be recorded at this time. Claims for damage after installation will not receive consideration. • Black Enamel panels will discolor a little during normal operation.
INSTALLATION GLASS CRYSTALS OR OPTIONAL STONES INSTALLATION ON BURNER Spread the Glass Crystals or Stones evenly over the burner. Ensure the crystals/stones do not overlap excessively as this will affect the flame pattern. IMPORTANT NOTE: Only the supplied approved Glass Crystals and Stones are to be used with these fireplaces. Use of any other type of glass crystals or stones can alter the unit's performance, any damage caused by the use of any unapproved glass or stones will not be covered under warranty.
INSTALLATION Glass Crystals shown on Burner For Units HZ54E, , HZ42ST, HZ42STE, HZI234E, HZ42E, HZ42, HZ30E, HZO42, HZO42 (AUS) PTO30, PTO60, Plateau Series Optional Spa Stones + Glass Crystals shown on burner.
INSTALLATION OPTIONAL DRIFTWOOD LOG SET INSTALLATION Read the instructions below carefully and refer to the images. If the logs are broken do not use the unit until they are replaced. Broken logs can interfere with pilot operation. Improper positioning of the logs may create carbon build-up and can alter the unit's performance which is not covered under warranty. *Satin black paint is included if touch ups are required.
INSTALLATION 10. Position Left Log (2) by matching the log and template profiles exactly. 15. Place Front Left log piece on firebox floor as shown. 1 2 6 HZ54E shown - Left Log (2) positioned to match template profile. 2 HZ54E shown - Left Log Piece(6) 16. Place Right Log piece on firebox floor as shown. 11. Position Right Log (3) by matching the log and template profiles exactly. 1 7 4 3 HZ54E shown - Right Log (3) positioned to match template profile. HZ54E shown - Right Log Piece(7) 17.
INSTALLATION GLASS DOOR INSTALLATION The glass door comes with a black frame. 1) To install the frame and glass door, simply hook the top door flange onto the top of the unit and swing the door towards the unit, Diagram 1. 2) With the door in proper position - secure with 2 screws in locations shown in Diagram 3. Note: Be careful that the glass gasket does not roll up; there must be a gap between the gasket and the door lip to ensure that the door sits securely on the unit. See Diagram 2.
INSTALLATION OPTIONAL MESH GLASS GUARD 1) Remove left side and right side door frame screws. 3) Install mesh screen, flush side facing out. 4) Install left side and right side top mounting clips approximately 3" from each side. 2) Using existing door frame screw, install lower mesh mounting brackets on left side and right side, as shown. NOTE: Clips should line up with the edge of the outer edge of the glass door flange - see glass door install for illustration.
INSTALLATION 4 PIECE FACEPLATE INSTALLATION 1) If installing optional mesh glass guard - See optional "Mesh Glass Guard" installation instructions. 2) Install brackets onto the back of the faceplate - 3 screws for each bracket in locations shown below. Hook bracket over these tabs 3) To install the 4 pc. faceplate - hook brackets (located on back of faceplate) over the two middle tabs on the glass door frame. If thicker finishing materials are used - the faceplate may be adjusted out - up to 1/2".
INSTALLATION INNER AND OUTER DOOR FRAME INSTALLATION Note: HZ40E only - if installing optional mesh glass guard See optional mesh glass guard instruction in the manual. Bracket in Unit Tab on Faceplate 1) Install 4 magnets onto 4 corners of glass frame prior to installing the inner door frame. 2) Install the inner door frame - fit it over the glass door frame.
OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS LIGHTING PROCEDURE 1) Read and understand these instructions before operating this appliance. IMPORTANT To ignite or reignite the pilot, you must first remove the glass door. 2) Check to see that all wiring is correct and enclosed to prevent possible shock. 3) Check to ensure there are no gas leaks. 4) Make sure the glass in the glass door frame is properly positioned. Never operate the appliance with the glass removed.
OPERATING INSTRUCTIONS INSTALLATION COPY OF LIGHTING PLATE INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTING This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
MAINTENANCE MAINTENANCE INSTRUCTIONS 1) Always turn off the gas and electrical supply before cleaning. For relighting, refer to lighting instructions. Keep the burner and control compartment clean by brushing and vacuuming at least once a year. 2) Clean appliance and door with a damp cloth (never when unit is hot). Never use an abrasive cleaner. The glass should be cleaned with a gas fireplace glass cleaner. The glass should be cleaned when it starts looking cloudy.
MAINTENANCE VALVE ASSEMBLY REPLACEMENT 1) Turn the unit off and allow it to cool down to room temperature. 8) Remove the burner by sliding it to the right - then lift out. 2) Shut off the gas and power supply to the unit. 3) Remove the faceplate or door frame -see instruction in this manual. 4) Remove the glass door. a) Remove the 3 screws shown below at the bottom of the glass door. b) Swing the door out 45o from the bottom and lift up and out.
PARTS LIST MAIN ASSEMBLY Part # Description 1 256-038 Frame Door HZ40E 2 940-361/P Glass Neoceram Flush HZ40E 3 256-039 Bottom Tray HZ40E 4 5 256-525 Burner Assembly NG c/w Cap HZ40E 256-530 Burner Assembly LP c/w Cap HZ40E 904-345 Orifice #53 LP 904-593 Orifice #40 NG 4 1 3 Part # Description 6 911-024 Valve NG 880 SIT IPI 911-025 Valve LP 880 SIT IPI 7 911-006 Pilot Assembly IPI NG 911-007 Pilot Assembly IPI LP 8 256-574E/P Valve Assembly HZ40E NG SIT 256-576E/P Valv
PARTS LIST ACCESSORIES Part # Description Part # Description 10) 256-908 Black Enamel Inner Panels 11) 256-954 256-956 256-957 Faceplate Black Faceplate Sunset Bronze Faceplate Brushed Stainless 946-700 946-701 946-702 GT Remote Control GTM Remote Control GTMF Remote Control 946-693 946-694 Modulator NG Modulator LP 256-934 256-936 256-947 Outer Door Frame Black Outer Door Frame Bold Outer Door Frame Stainless 256-944 256-946 256-947 Inner Door Frame Black Inner Door Frame Bold Inner Door F
NOTES 64 Regency Horizon™ HZ40E-2 Gas Fireplace
NOTES Regency Horizon™ HZ40E-2 Gas Fireplace 65
NOTES 66 Regency Horizon™ HZ40E-2 Gas Fireplace
WARRANTY Regency® Fireplace Products are designed with reliability and simplicity in mind. In addition, our internal Quality Assurance Team carefully inspects each unit thoroughly before it leaves our facility. Regency® Fireplace Products is pleased to extend this limited lifetime warranty to the original purchaser of a Regency® Product. This warranty is not transferable.
Register your Regency® warranty online www.regency-fire.com Reasons to register your product online today! • View and modify a list of all your registered products. • Request automatic email notification of new product updates. • Stay informed about the current promotions, events, and special offers on related products.