Specification

Hammer-Set Anchor - Technical Data
PART
NUMBER
DESCRIPTION
In. (mm)
DRILL SIZE
In. (mm)
MAX. FIXTURE
THICKNESS
In. (mm)
MIN.
EMBEDMENT
In. (mm)
MIN. HOLE
DEPTH
In. (mm)
QTY/WT
PER BOX
lbs.
QTY/WT
PER MASTER
CTN - lbs.
HS-1607 3/16 x 7/8 (4.8 x 22.2) 3/16 (4.8) 1/4 (6.4) 5/8 (15.9) 1-1/8 (28.6) 100/ 2.0 1000/ 20
HS-1406 1/4 x 3/4 (6.4 x 19.1) 1/4 (6.4) 1/8 (3.2) 5/8 (15.9) 1 (25.4) 100/ 2.2 1000/ 22
HS-1410 1/4 x 1 (6.4 x 25.4) 1/4 (6.4) 1/4 (6.4) 3/4 (19.1) 1-1/4 (31.8) 100/ 2.4 1000/ 24
HS-1412 1/4 x 1-1/4 (6.4 x 31.8) 1/4 (6.4) 1/2 (12.7) 3/4 (19.1) 1-1/2 (38.1) 100/ 2.6 1000/ 26
HS-1414 1/4 x 1-1/2 (6.4 x 38.1) 1/4 (6.4) 3/4 (19.1) 3/4 (19.1) 1-3/4 (44.5) 100/ 2.8 1000/ 28
HS-1420 1/4 x 2 (6.4 x 50.8) 1/4 (6.4) 1-1/4 (31.8) 3/4 (19.1) 2-1/4 (57.2) 100/ 3.5 1000/ 35
SELECTION CHART
PERFORMANCE TABLE
Ultimate Tension and Shear
Values in Concrete (Lbs/kN)
ANCHOR DIA.
In. (mm)
MIN. DEPTH OF EMBEDMENT
In. (mm)
4000 PSI (27.6 MPa)
TENSION Lbs. (kN) SHEAR Lbs. (kN)
3/16” (4.8) 5/8” (15.9) 500 (2.2) 450 (2.0)
1/4” (6.4) 5/8” (15.9) 700 (3.1) 700 (3.1)
1/4” (6.4) 3/4” (19.1) 800 (3.5) 800 (3.5)
1/4” (6.4) 1” (25.4) 950 (4.2) 800 (3.5)
1/4” (6.4) 1-1/4” (31.8) 1,100 (4.9) 1,100 (4.9)
Safe working loads for single installations under static loading
conditions should not exceed 25% of the ultimate capacity. Divide ultimate values by 4.