Installation Manual

2 www.rayteccctv.com UK / Europe Tel: +44 (0) 1670 520055
Americas Tel: +1 613 270 9990
Installation Steps – Quick Guide
1. VARIO is factory set and delivered with a 35˚
beam width.
To alter to 10˚, simply remove interchangeabIe
holographic diffuser (IHD). See page 3 for
detailed instructions
To alter to 60˚, replace with other IHD supplied.
2. Mount Illuminator
3. Connect Illuminator to low voltage input 12/24V
AC/DC
4. Complete configuration and final set-up using
VARIO Remote Controller (VRC) - this is an
optional accessory
Photocell
Cable
Breather
Gland
Wiring - six core cable
White & Yellow wires =
Photocell following contact.
Volt free output. Non polarity sensitive.
Orange & Purple wires =
Telemetry input Volt free/dry contact or
TTL input
(See Page 4 - Step 5 for more details)
DC AC
Black wire - ~
Red wire + ~
IR Variants
CAUTION - IR emitted from this product – Risk Group 2. Do not stare at the lamp.
Avoid exposure or use appropriate shielding / eye protection. Risk Group 2 for
cornea / lens infrared hazard.
At a distance of more than 1500mm for all products the unit is in the exempt
group.
White Light Variants
Risk Group 1 classification. Do not stare at the lamp.