Installation and Operating Manual Metor 900M P/N 101023281 – Rev. 0.
Page 2 Metor 900M P/N 101023281 Installation and Operating Manual Rev. 0.5 Foreword Thank You for choosing a Metor product. This manual is intended for the installation and normal daily use of the equipment. In addition to these instructions, local laws and regulations, and requirements by authorities shall be observed. The user should read this manual and understand its contents before the installation or use of the equipment.
P/N 101023281 Rev. 0.5 Metor 900M Installation and Operating Manual Revision History Name of Document: Installation and Operating Manual, Metor 900M Document Number: 101023281 Rev. Date Comments 0.1 2019-02-12 First draft. 0.2 2019-06-12 Updates to installation and user interface. 0.3 2020-01-24 Updates to user interface chapter. 0.4 2020-03-10 Added FCC statement. 0.5 2020-04-21 Modified FCC statement.
Page 4 Metor 900M P/N 101023281 Installation and Operating Manual Rev. 0.5 Table of Contents 1 IMPORTANT INSTRUCTIONS .................................................................................................... 6 1.1 1.2 2 INTRODUCTION ......................................................................................................................... 8 2.1 2.2 2.3 2.4 2.5 3 Types of Alert Messages ........................................................................................
P/N 101023281 Rev. 0.5 Metor 900M Page 5 Installation and Operating Manual APPENDIX A: Definition of Terms .................................................................................................... 33 APPENDIX B: Contact Information ...................................................................................................
Page 6 Metor 900M P/N 101023281 Installation and Operating Manual 1 Rev. 0.5 IMPORTANT INSTRUCTIONS Read through this chapter carefully before operating the equipment. Keep this manual so that it is always readily available to the user. The instructions in this manual shall be followed in all situations, when installing, using, or servicing the equipment. Rapiscan Systems cannot be held responsible for any personal or material damage caused by use contradicting the instructions given in this manual.
P/N 101023281 Rev. 0.5 1.1 Metor 900M Page 7 Installation and Operating Manual Types of Alert Messages WARNING Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. CAUTION Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury and/or equipment damage or generally unsafe practices.
Page 8 Metor 900M P/N 101023281 Installation and Operating Manual 2 2.1 Rev. 0.5 INTRODUCTION Intended Use Metor 900M is a walk-through metal detector (WTMD) designed to detect metal objects people are carrying with them. The product is used primarily for weapons detection.
P/N 101023281 Rev. 0.5 2.2 Metor 900M Page 9 Installation and Operating Manual Product Safety Metor 900M has been tested against and complies with applicable magnetic field standards concerning human exposure and pacemaker safety. Metor 900M conforms to the applicable international standards for electrical safety and electromagnetic compatibility. WARNING Following warning is required by NIJ Standard-0601.
Page 10 Metor 900M P/N 101023281 Installation and Operating Manual 2.3 Rev. 0.5 Main Components 1. 2. 3. 4. 5. Cross piece including display and keypad (MCES5322-30) Electronics set, inside cross piece, (MELS5317) AC/DC power supply set, inside cross piece (MPSS5321) Transmitter panel set, i.e. TX panel, (MTXS5326) Receiver panel set, i.e.
P/N 101023281 Metor 900M Rev. 0.5 2.4 Page 11 Installation and Operating Manual Battery Backup Set A battery backup accessory MBBS5332, Rapiscan part number 101010726, is available for emergency power in case of power outage. The battery backup guarantees uninterrupted operation in case of a temporary power outage. The unit is installed inside the cross piece. For more information on battery backup refer to its manual. 2.5 Technical Data Power • • • • • • Voltage, nominal .........................
Page 12 Metor 900M P/N 101023281 Installation and Operating Manual 3 Rev. 0.5 INSTALLATION When planning the installation of a WTMD there are a few important things that should be considered. The optimum operation of the WTMD as well as maximum traffic flow at the security checkpoint can be ensured only when these factors have been taken into account. 3.
P/N 101023281 Rev. 0.5 Page 13 Metor 900M Installation and Operating Manual Moving Metal Moving metal objects Large moving metal objects outside the WTMD should be kept at least 0.5 - 2 m (20 - 79 in) away from the WTMD to avoid false alarms. The required distance between the moving metal and the WTMD varies depending on the size of the metal object and the sensitivity setting of the WTMD.
Page 14 Metor 900M P/N 101023281 Installation and Operating Manual 3.3 Rev. 0.5 Side-by-Side Operation Side-by-side operation means that two or more Walk Through Metal Detectors operate close to each other. When operated side-by-side, WTMDs may interfere with each other to some extent. The level of interference depends on the distance between the units, their operating frequencies and selected detection sensitivity.
P/N 101023281 Rev. 0.5 3.4 Page 15 Metor 900M Installation and Operating Manual Mechanical Assembly The items needed in mechanical assembly are packed in the box containing the cross piece. For checking the distance of the coil panels there is a pasteboard gauge in the cross piece box. Ref Part Pcs 1............ TX panel ......................... 1 2............ RX panel ........................ 1 3............ Cross piece .................... 1 5............ Mounting screws.............
Page 16 Metor 900M P/N 101023281 Installation and Operating Manual 3.5 Rev. 0.5 Floor Fixing • • • • • • Lift the unit up to a vertical position in its final mounting location. Check that the panels are parallel both in walking direction and sidewise. Use the pasteboard gauge provided to ensure that distance between panels is the same at top and at bottom. Tighten the mounting screws. Use the mounting holes (1) in the panel boots to fix the unit to the floor with screws.
P/N 101023281 Rev. 0.5 3.6 Page 17 Metor 900M Installation and Operating Manual Electrical Connections • • Open cross piece hatch to access connections to the electronics. Mains power cord can be connected either to AC jumper cable in TX panel or, if mains connection is on ceiling, it can be taken into the cross piece using lead-ins on upper inner edge of the panels and connected directly to power supply. Connections: 1. RX panel coil connector 2.
Page 18 Metor 900M P/N 101023281 Installation and Operating Manual 3.7 Rev. 0.5 Connections for Digital I/O The Metor 900M has two configurable digital inputs and two configurable digital outputs. The digital inputs have a pull-up resistor to 3.3 V. Maximum input voltage is 5 VDC. Recommended connection is a switch that connects input (pin 3) to ground (pin 1). Maximum load for each relay output is 24 V and 1 A.
P/N 101023281 Rev. 0.5 4 Page 19 Metor 900M Installation and Operating Manual STARTUP AND SHUTDOWN • • • • Metor 900M is turned on and off from the power switch on the main electronics inside the cross piece. To access the switch open the cross piece hatch with the key provided. The unit can be switched to standby without the need to open the cross piece hatch by enabling the standby feature from the user interface. Standby state is turned on and off from keypad on the cross piece.
Page 20 Metor 900M P/N 101023281 Installation and Operating Manual 5 Rev. 0.5 DISPLAYS AND KEYPAD • • All functions of Metor 900M are controlled using the keypad and the graphical display on the cross piece. During normal operation the status of the unit is shown on status LED display and the graphical display. Cross piece has: 1. 2. 3. 4. Graphical display Keypad Status LED window IR window for communication with remote control.
P/N 101023281 Rev. 0.5 6 6.1 Metor 900M Page 21 Installation and Operating Manual USER INTERFACE Access to User Interface To adjust unit’s parameters or to use functions a user needs to enter the user interface: • Press key. • Select either SUPERUSER or USER using arrow keys and confirm selection with key. SUPERUSER has access to all user interface items while USER can only view and clear passenger and alarm counters. • Enter password followed by .
Page 22 Metor 900M P/N 101023281 Installation and Operating Manual 6.3 Users Menu Item CHANGE PASSWORD 6.4 Rev. 0.5 Possible values Default setting Description - - Change SUPERUSER or USER password. Random Menu Metor 900M has three random alarm generators. The generators can be individually configured and can be simultaneously in operation. All generators have same parameters.
P/N 101023281 Metor 900M Rev. 0.5 Item Page 23 Installation and Operating Manual Possible values Default setting Description RND1 ZONE PATTERN 0–4 1 Selection of zone display pattern during random alarms. 0: no zone display. 1: segments in the middle are lighted. 2: every second segment is lighted. 3: every third segment is lighted. 4: every fourth segment is lighted. Note that if zone displays are disabled in Audio/Visual menu no random zone pattern are shown.
Page 24 Metor 900M P/N 101023281 Installation and Operating Manual Rev. 0.5 NOTICE Maximum value of counters is 4 294 967 295. Should a counter ever reach its maximum value it will stay at the maximum value. Use the function “CLEAR STATISTICS” to reset counters. 6.6 Detection Menu Item Possible values Default setting SENSITIVITY 1 - 200 100 PROGRAM see following table Description Selection of overall detection sensitivity.
P/N 101023281 Metor 900M Rev. 0.5 Installation and Operating Manual Metor 900M DETECTION PROGRAMS Name Decription CRITICAL INFRASTRUCTURE CI1 CI2 CI3 CI4 AVIATION EU1 ECAC level 1 EU2 ECAC level 2 MASS TRANSIT MT1 MT2 HIGH FOOTFALL HF1 HF2 HF3 HF4 LAW ENFORCEMENT LE1 LE2 NIJ LARGE NIJ Standard-0601.02 large object size NIJ MEDIUM NIJ Standard-0601.
Page 26 Metor 900M P/N 101023281 Installation and Operating Manual 6.7 Rev. 0.5 Audio/Visual Menu Item Possible values Default setting Description ALARM VOLUME 0 - 9 5 Selection of audible alarm volume. When value is 0 alarm is muted. Volume cannot be less than value set by ALARM VOL MIN parameter. Note that volume can also be adjusted directly using key without entering user interface. ALARM VOL MIN 0 - 9 2 The minimum value to which audible alarm volume can be adjusted.
P/N 101023281 Metor 900M Rev. 0.5 Page 27 Installation and Operating Manual Item Possible values TL RED ON TIME 0.0 – 6.0 s POWER INDICATION EXIT ENTRY BOTH OFF Default setting Description 0.0 s Selection of the time traffic lights stay red after passenger exits the unit. In case of an alarm traffic lights stay red as long as there is an alarm indication. EXIT Selection of the side(s) on which power indication is shown. Power indication is green lights on top segment of zone displays.
Page 28 Metor 900M P/N 101023281 Installation and Operating Manual 6.9 Rev. 0.5 NFC Menu Metor 900M is equipped with NFC capability. You can use Rapiscan supplied NFC cards to quickly change unit’s parameter values. NFC read area is indicated by NFC symbol on the cross piece between status LED window and display. Item Possible values Default setting Description NFC ENABLE YES/NO NO Selection of whether NFC functionality is enabled or not.
P/N 101023281 Metor 900M Rev. 0.5 Item Page 29 Installation and Operating Manual Possible values Default setting Description OFF Configuration of digital input2. Same values as for input1. If both inputs are configured for same operation a logical OR is made between them. In case of two conflicting simultaneous inputs priority is following: 1. MANUAL ALARM 2. ALARM INHIBIT OUTPUT1 OFF ALARM PAX OFF Configuration of relay output1. OFF: output is disabled.
Page 30 Metor 900M P/N 101023281 Installation and Operating Manual 7 7.1 Rev. 0.5 MAINTENANCE Periodic Maintenance The Metor 900M is virtually maintenance-free. However, the operation should be checked regularly, preferably daily, to ensure that the security is not compromised. For additional information on maintenance please refer to the Maintenance Manual. 7.2 Replacing Input Fuse Inside the electronics (MELS5317) there is a 5.0AT fuse F9 protecting the electronics.
P/N 101023281 Rev. 0.5 8 8.1 Page 31 Metor 900M Installation and Operating Manual TROUBLESHOOTING Fault Conditions Fault Possible cause Recommended actions Random alarming External interference Change operating frequency. Relocate the unit. Reduce sensitivity. High interference level Selected frequency not suitable for the environment Change operating frequency. Interference source close to the unit Remove interference source or relocate the unit.
Page 32 Metor 900M P/N 101023281 Installation and Operating Manual 9 Rev. 0.5 DISPOSAL OF EQUIPMENT When the equipment is taken out of use, it should be disposed of by observing the following environmental aspects: • • • • The steel and aluminum of the equipment structures, the copper of the cables, and the precious metals in the electronics should be recycled as raw materials and used for production of new metal products.
P/N 101023281 Rev. 0.5 Metor 900M Page 33 Installation and Operating Manual APPENDIX A: Definition of Terms Some special terms used in this manual are explained below. WTMD - Walk Through Metal Detector Sensitivity - Parameter for defining the size of the metal items that will generate an alarm. When sensitivity is increased smaller metal items will be detected. Discrimination - The WTMD’s ability to differentiate harmless items from weapons.
Page 34 Metor 900M P/N 101023281 Installation and Operating Manual Rev. 0.5 Detection uniformity - The ability of a WTMD to maintain uniform sensitivity throughout the whole detection area regardless of the shape and orientation of the metal item. Detection uniformity directly affects the discrimination capability of a WTMD. The sensitivity of a WTMD is usually set according to the weakest position of the detection area.
P/N 101023281 Rev. 0.5 Metor 900M Installation and Operating Manual APPENDIX B: Contact Information Customer Service and Support Email: Skype: RSSupport@rapiscansystems.com RSSupport Center The Americas and Caribbean Telephone: +1-310-349-2477 Toll Free: +1-888-258-6684 Canada Toll Free: +1-800-335-6274 Email: RapCSCallCenter@rapiscansystems.com Europe, Middle East and Africa Telephone: +44-0-8707-774301 Email: RSPUK-AllService@rapiscansystems.com Email: Rapmeso@rapiscansystems.