Quick Start with keyboard shortcuts (200k)
RANE SL 1 FOR SERATO SCRATCH LIVE • QUICK START 2.4
3
Calibration
2. Press and hold the estimate button
for each side, letting go when the
threshold setting is stable (usually about
one second). In situations with lots of
background noise, the threshold will
need to be higher.
3. Start the motors, and adjust the L/R
balance and P/A balance next to each
calibration scope to adjust the shape
of the inner ring. Use the scope zoom
slider (1x to 16x) to zoom in or out as
necessary. Note: If you have trouble
getting the rings circular, try cleaning
or changing your needles. If the image
appears as a line, then one channel
of the turntable is not working. See
examples of SCOPE READING AND
FIXES in the manual.
4. Check the percentage (%) in the bottom
right corner of each calibration scope,
indicating the percentage of readable
signal — this number should be close
to 100% when your system is calibrated
properly.
These are the basics of calibrating. If
you run into any problems or questions,
we really recommend reading the
CALIBRATING SCRATCH LIVE on page 8
of the manual. If you aren’t seeing good
circles, refer to the SCOPE READING AND
FIXES page on page 28 of the manual.
After your setup is calibrated properly you
are ready to import music. See page 9 in
the manual to get started.
CALIBRATING SCRATCH LIVE
When setting up Scratch Live in a new
location, calibrate the software to the
background noise picked up by the
needles, cables and CD players.
1. When using turntables, place the
needles on the records with the motors
off and switch to the setup screen.
When using CD players, pause the CD
and switch to the setup screen.