Owner's manual
AT27BV4096
4
Notes: 1. V
CC
must be applied simultaneously with or before V
PP
, and removed simultaneously with or after V
PP
.
2. V
PP
may be connected directly to V
CC
, except during programming. The supply current would then be the sum of I
CC
and I
PP
.
DC and AC Operating Conditions for Read Operation
AT27BV4096-12 AT27BV4096-15
Operating Temperature
(Case)
Com. 0°C - 70°C0°C - 70°C
Ind. -40°C - 85°C-40°C - 85°C
V
CC
Power Supply
2.7V to 3.6V 2.7V to 3.6V
5V ± 10% 5V ± 10%
DC and Operating Characteristics for Read Operation
Symbol Parameter Condition Min Max Units
V
CC
= 2.7V to 3.6V
I
LI
Input Load Current V
IN
= 0V to V
CC
±
1
µ
A
I
LO
Output Leakage Current V
OUT
= 0V to V
CC
±
5
µ
A
I
PP1
(2)
V
PP
(1)
Read/Standby Current V
PP
= V
CC
10
µ
A
I
SB
V
CC
(1)
Standby Current
I
SB1
(CMOS), CE = V
CC
±
0.3V 20
µ
A
I
SB2
(TTL), CE = 2.0 to V
CC
+ 0.5V 100
µ
A
I
CC
V
CC
Active Current f = 5 MHz, I
OUT
= 0 mA, CE = V
IL
, V
CC
= 3.6V 10 mA
V
IL
Input Low Voltage
V
CC
= 3.0 to 3.6V -0.6 0.8 V
V
CC
= 2.7 to 3.6V -0.6 0.2 x V
CC
V
V
IH
Input High Voltage
V
CC
= 3.0 to 3.6V 2.0 V
CC
+ 0.5 V
V
CC
= 2.7 to 3.6V 0.7 x V
CC
V
CC
+ 0.5 V
V
OL
Output Low Voltage
I
OL
= 2.0 mA 0.4 V
I
OL
= 100
µ
A0.2V
I
OL
= 20
µ
A0.1V
V
OH
Output High Voltage
I
OH
= -2.0
mA 2.4 V
I
OH
= -100
µ
AV
CC
- 0.2 V
I
OH
= -20
µ
AV
CC
- 0.1 V
V
CC
= 4.5V to 5.5V
I
LI
Input Load Current V
IN
= 0V to V
CC
±
1
µ
A
I
LO
Output Leakage Current V
OUT
= 0V to V
CC
±
5
µ
A
I
PP1
(2)
V
PP
(1)
Read/Standby Current V
PP
= V
CC
10
µ
A
I
SB
V
CC
(1)
Standby Current
I
SB1
(CMOS), CE = V
CC
±
0.3V 100
µ
A
I
SB2
(TTL), CE = 2.0 to V
CC
+ 0.5V 1 mA
I
CC
V
CC
Active Current f = 5 MHz, I
OUT
= 0 mA, CE = V
IL
40 mA
V
IL
Input Low Voltage -0.6 0.8 V
V
IH
Input High Voltage 2.0 V
CC
+ 0.5 V
V
OL
Output Low Voltage I
OL
= 2.1 mA 0.4 V
V
OH
Output High Voltage I
OH
= -400
µ
A2.4V