User's Manual

Hardware Installation Chapter 2
The RADWIN 6000 ODU must be grounded to a Protective Earth as described in
and in accordance with the Local Electrical Regulations.
Further, you should -
Always make the ground connection first and disconnect it last
Never connect telecommunication cables to ungrounded equipment
Ensure that all other cables are disconnected before disconnecting the ground
Protection against Lightning
The use of lightning protection is dependent on regulatory and end user requirements. All
of RADWIN outdoor units are designed with surge limiting circuits to minimize the risk of
dam-age due to lightning strikes. RADWIN recommends the use of additional lightning
protector devices to protect the equipment from nearby lightning strikes.
See Chapter 3 for detailed installation instructions of lightning protection devices.
General
It is recommended that installation of an outdoor unit be contracted to a professional
installer.
Before working on equipment connected to power lines or telecommunication lines,
you should remove jewelry or any other metallic object that may come into contact
with energized parts.
Use extreme care when installing antennas near power lines.
Use extreme care when working at heights.
When using an AC power source for RADWIN 6000 PoEs always use the AC power
adapter supplied by RADWIN.
Use the right tools. In addition to standard tools required for any kind of ODU or
antenna installation, RADWIN 6000 ODUs require additional specific tools detailed on
page 2-4 below.
Package Contents
The RADWIN 6000 packages include the following items:
One RADWIN 6000- see Figure 2-5 below for front and rear view
An ODU mounting kit - see Figure • below
A CD containing -
the RADWIN Manager
User Manual
Label showing the MAC address and the alternative Community string. The label is
self-adhesive. You should keep this label safe
Two cable glands (to be used with CAT 5e cables)
One AC/DC cable gland
One 0.5 meter 10 AWG grounding cable
AC Power cable RADWIN 6000 Mounting kit
RADWIN 6000 Reference Guide Release 6.1.00p8 2-2