User's Manual

Hardware Installation Chapter 2
Tools and Materials
Crimping tool for RJ-45 (if the ODU-PoE cable is without connectors)
Spanner/wrench 13 mm (½”)
Drill (for wall mounting only)
Cable ties
Sealing material
Cables and connectors
CAT 5e LAN cable
PoE-out cable (outdoor class, CAT-5e, 4 twisted pairs, 24AWG), up to 100 m. for
100BaseT connection. For a 1000BaseT connection (HBS only) use an ODU-PoE cable
no longer than 75m.
For 1000BaseT, you should use RADWIN supplied ODU-PoE cables, which
guarantee 1Gb performance. RADWIN cannot guarantee 1Gb performance
Note if you use third party cables.
Outdoor installation
Mounting the ODU
The ODU can be mounted on a pole or a wall. In both installations, the supplied mounting
kit is used to secure the ODU.
A mast-sited ODU typically uses a pole attached to the mast.
Note
Prior to connecting cables to the ODU, the protective earth terminal (screw)
of the ODU must be connected to an external protective ground conductor
or to a grounded pole.
Warning
• Only a qualified person using the proper safety equipment should
climb the antenna mast
• Only qualified professional personnel should install or dismantle
ODUs and masts
To mount the ODU on a pole or a wall:
1. Ensure that the ODU is properly grounded.
2. Mount the ODU onto the pole or wall. Ensure that the unit is oriented so that the
cable connectors are at the bottom. (If they are on top, water may penetrate
into the unit causing damage.) It is possible to mount an ODU horizontally.
3. Refer also to for detailed ODU mounting kit contents and schematics.