Instructions

Model No.
Date
QU-TK-F3x
2019/1/10
1.03
Communication Protocol
QUIO
Ver.
Page
QU-TK-F3 Series
20 / 52
ATR (Answer to Reset) format:
TS TO TA1
TB1
TCK
See details from ISO7816 standard
Vcc=30H: ICRW supplies with +5V to VCC and activates in line with the EMV2000 ver4.0.
Vcc=33H: ICRW supplies with +5V to VCC and activates in line with the ISO/IEC7816-3.
Vcc=35H: ICRW supplies with +3V to VCC and activates in line with the ISO/IEC7816-3.
In case there is no Vcc provided, it will have 30H as default value
If ATR is not compliance to EMV, return e1,e0=“69”
Notes: There will be error and return ATR & Type when reset in line with EMV return
When a power failure is recognized while a power supply is supplied to the card, error code
"
60" is returned.
9
.7.2 Deactivate SAM Command
HOST Command
C” 52H 31H
Positive response
P” 52H 31H
st0
e1
st1
e0
st2
Negative response
N” 52H 31H
This deactivates SAM
9
.7.3 Inquire SAM Status Command
HOST Command
C” 52H 32H
Positive
response
P” 52H 32H
st0
st1
st2
Sti
Stj
Negative response
N” 52H 32H
e1
e0
QU-TK-F31 returns the status of SAM with sti. stj
Sti =30H SAM is deactivated
Sti =31H SAM is activated, working frequency is 3.57 MHZ
Sti =32H SAM is activated, working frequency is 7.16 MHZ
Stj =30H First SAM card connector
Stj =31H Second SAM card connector (Optional)
QUIO
https://www.quio-rfid.de Email: kontakt@quio-rfid.de