Thermostat Junction Box Wall Stud Connection Junction Box Romex 12/2 Conduit Conduit to Thermostat Lead Wire Conduit To Bottom Plate Wall Stud Sensor Wire Conduit NOTE: Drill into Base Plate as needed to allow Lead and Sensor Wires to be run to Thermostat Leads From Elements Leads From Elements Sensor Wire Alternatively, you can use the notch method. Cut/chisel a notch in the bottom plate to allow clearance for Lead and Sensor Wires.
Sensor located 6-12” from wall Thermostat Sensor
Floor Not Warming Verfiy power is connected to the system and that the GFCI is not tripped at the thermostat or the circuit breaker is not tripped at the main service panel. Ensure the right voltage is applied to the purchased mats. Mat Not Warming Verify that all leads from all mats are connected together to power source. Areas within a mat that are not heating could be the result of damage and will require the mat to be replaced.