Owner's Manual
9
TD-000371-00-A
Specifi cations
Refer to the individual sections in this document for more information. Specifi cations are subject to change.
Parameter Specifi cation Parameter Specifi cation
Dimensions (H/W/D): 1.75" x 19" x 15"
Audio Performance (DataPort Outputs)
Line voltage requirements 100 VAC – 240 VAC, 50/60 Hz
Dynamic range
(unweighted):
>107 dB
Accessories included 6 ft. UL/CSA line cord, Connector Kit
THD+N at +12 dBu input
level (per AES-17)
<.005 %
Front Panel Controls
Frequency response 20 Hz to 20 kHz
LCD page forward Momentary switch D/A conversion 24-bit delta-sigma, 48 kHz
Set parameter Momentary switch
DSP Performance
Indicators
Filter topology 24-bit digital IIR
Power-on indicator Green LED Crossover fi lters Linkwitz-Riley or Butterworth (6 - 48 dB/octave)
Status indicator Tri-color LED (Red, Green, Amber) Parametric EQ
Digital band-pass fi lter with ±20 dB of boost/
cut. Q is programmable in 1/10th octave steps
from 1/20th to 4 octaves
Menu-driven LCD 2 line x 16 character LCD CD Horn EQ
Digital shelf fi lter with up to ±10 dB of cut/boost
programmable from 20 Hz to 20 kHz
Rear Panel Connectors
All pass fi lter
2nd order all pass fi lter programmable from
20 Hz – 20 kHz
Universal Mic/Line input
XLR — Mic (+ phantom power) or line level
Available sensitivity settings:
-16 dBu, 10 dBu, 21 dBu, 27 dBu
Band polarity Normal, inverted
DataPort outputs HD-15 (x12) — QSC amplifi er interface Band delay
Programmable in 21 µs steps from 0 ms to
10 ms
Automation inputs 2-pin Euro-style (x2) Amplifi er AC Control
All amps power on with DXP activation and can
be placed into standby via user interface
Relay outputs 3-pin Euro-style (x4) – max 30 VDC
Automation Inputs
CobraNet
RJ45 (x2) 100 Mbps primary/backup network
audio
Input Type TTL Compatible or Dry Contact Closure
Audio Performance (Mic/Line Input)
Operating Mode
Connection to ground through a maximum
impedance of 1 k Ohm for closure detect
A/D conversion 24-bit delta-sigma, 48 kHz
Relay outputs
Dynamic range
(unweighted)
> 103 dB Output type Mechanical relay contacts
Input stage type Active balanced Compatible
Max 30 VDC output at 1 A. Can be wired as
NO or NC
Input impedance
Balanced: 6.81 k Ohms
Unbalanced: 13.6 k Ohms
Audio network / Control connection to DCP
Max analog input level
-16 10 21 27 dBu
Protocol CobraNet version 2 protocol
0.123 2.25 8.70 17.35 Vrms
CMRR typical (max) 20 Hz – 20 kHz >60 dB (>50 dB) Data rate 100 Mbps (Fast Ethernet)
THD+N at 2 dB below clip
(per AES-17)
<0.006% Ports 1 Primary, 1 Backup (auto-failover)
Connection requirements
CAT-5 UTP cable or better (100 m maximum
length), direct connection to wired network
switch ports only, dedicated LAN or V-LAN