AWH Series Installation Guide

WH Series
Fan Forced Wall Heaters
For use with FRC and
AWH Series wall heaters
WHEN USING ELECTRIC APPLIANCES, BASIC PRECAU-
TIONS SHOULD ALWAYS BE FOLLOWED TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK, AND INJURY TO PER-
SONS, INCLUDING THE FOLLOWING:
1. Read all instructions before installing or using this heater.
2. This heater is hot when in use. To avoid burns, do not let
bare skin touch hot surfaces. Keep combustible materials,
such as furniture, pillows, bedding, papers, clothes, etc. and
curtains at least 3 feet (0.9 m) from the front of the heater.
3. Extreme caution is necessary when any heater is used by or
near children or invalids and whenever the heater is left
operating and unattended.
4. Do not operate any heater after it malfunctions. Disconnect
power at service panel and have heater inspected by a rep-
utable electrician before using.
5. Do not use outdoors.
6. To disconnect heater, turn controls to off, and turn off power
to heater circuit at main disconnect panel.
7. Do not insert or allow foreign objects to enter any ventilation
or exhaust opening as this may cause an electric shock, fire,
or damage to the heater.
8. To prevent a possible fire, do not block air intake or exhaust
in any manner.
9. A heater has hot and arcing or sparking parts inside. Do not
use it in areas where gasoline, paint, or flammable liquids
are used or stored.
10. Use this heater only as described in this manual. Any other
use not recommended by the manufacturer may cause fire,
electric shock, or injury to persons.
11. This heater is intended for comfort heating applications and
not intended for use in special environments. Do not use in
damp or wet locations such as marine or greenhouse or in
areas where corrosive or chemical agents are present.
12. When installing, see INSTALLATION INSTRUCTIONS for
additional warnings and precautions.
13. For safe and efficient operation, and to extend the life of your
heater, keep your heater clean - See MAINTENANCE
INSTRUCTIONS.
SAVE THESE INSTRUCTIONS
!
Installation, Operation & Maintenance Instructions
WARNING
IMPORTANT INSTRUCTIONS
ECR 41127 10/16 5200-11207-003
Table 1. Specifications
Min.
Supply
Model Wire
Number Volts Phase Watts Amps Gauge
WH3150FC 120 1 1500 12.5 12
WH3180FC 120 1 1800 15.0 12
WH4404*FC 240
1
4000/2000 16.7/8.3 10
208 3000/1500 14.5/7.2 12
WH4407*FC 277
1
4000/2000 14.5/7.2 12
240 3000/1500 12.5/6.3 12
WH4307*FC 277 1 3000/1500 10.8/5.4 12
WH4408*FC 208 1 4000/2000 19.2/9.6 10
WH44083FC 208 3 4000 11.1 14
WH44043FC 240 3 4000 9.7 14
*NOTE: Factory wired for higher wattage, field convertible to half wattage.
Min.
Supply
Model Wire
Number Volts Phase Watts Amps Gauge
WH4303FC 347 1 3000 8.6 14
WH4306FC 600 1 3000 5 14
WH4508FC 208 1 4800 23.1 10
WH4504FC 240 1 4800 20.0 10
208 3600 17.3
WH4507FC 277 1 4800 17.3 10
240 3600 15.0
WH45083FC 208 3 4800 13.3 12
WH45043FC 240 3 4800 11.6 14
WH4503FC 347 1 4800 13.8 12
WH4506FC 600 1 4800 8 14
*NOTE: Factory wired for higher wattage, field convertible to half wattage.
19-5/16"
(506.4mm)
15-3/4"
(400mm)
Conforms to
ANSI/UL 2021 and
CSA C22.2 No. 46
18-1/4"
(464mm)
14-3/8"
(365mm)
1-1/4"
(32mm)