SDS

SAMSUNG SDI Co., Ltd.
Date: Jan 7
th
2020 Revision no.: 01
ELG(P11P35-11-N01,3.7L1200SPA)
Page 8 of 22
(respirable
particulate
matter); TWA =
0.1 mg/m
3
(inhalable
particulate
matter)
(Manganese
compounds (as
Mn), Manganese
fume (as Mn))
(inhalable
fraction)
8.2 Exposure controls
8.2.1 Appropriate engineering controls :
Substance/mixture related measures to prevent exposure during identified uses:
- Avoid charging batteries in areas where hydrogen gas accumulate.
- Use local exhaust ventilation to maintain concentrations of hydrogen below the Lower Explosive
collect and transport flammable gases in ventilation systems.
- Insure proper ventilation is present and electrolyte mist and vapours.
Structural measures to prevent exposure:
- Avoid charging batteries in areas where hydrogen gas accumulate.
- Use local exhaust ventilation to maintain concentrations of hydrogen below the Lower Explosive
collect and transport flammable gases in ventilation systems.
- Insure proper ventilation is present and electrolyte mist and vapours.
Organisational measures to prevent exposure: Not available
Technical measures to prevent exposure:
- Insure proper ventilation is present and electrolyte mist and vapours.
8.2.2 Individual protection measures, such as personal protective equipment :
Eye and face protection
- Wear ANSI approved safety glasses with side shield during normal use.
- Wear NIOSH approved face shield with safety glasses and H.V protection during intentional
disassembly.
Skin protection
Hand protection
- Wear nitrile butyl rubber, neoprene, or PVC glove during battery component disassembly.
- Discard contaminated work clothing after one work day.
Other skin protection
- Wear protective clothing during battery component disassembly.
- Discard contaminated work clothing after one work day.
Respiratory protection :
- None required during normal use.
- Wear NIOSH or European Standard EN 149 approved full or half face piece (with goggles)
respiratory protective equipment when necessary.