Mini Led Spot Full Color PLLED185 MANUALE UTENTE USER MANUAL 1 Rev.
Indice 1. Introduzione 4 1.1 Contenuto della confezione 1.2 Istruzioni per l'apertura dell'imballo 1.3 Alimentazione 1.4 Istruzioni di sicurezza 2. Introduzione 4 4 4 4 5 2.1 Caratteristiche 2.2 Canali DMX 5 5 3. Setup 5 3.1 Sostituzione fusibile 3.2 Collegamento di più apparecchi 3.3 Conversione tra un connettore 3 poli e 5 poli 3.4 Creazione di una catena DMX 3.5 Collegamento Master / Slave 3.6 Installazione 4. Istruzioni operative 5 5 6 6 6 6 7 4.1 Pannello di controllo 4.2 Menu 4.
Table of contents 1. Preface 10 1.1 Packing list 1.2 Unpacking instructions 1.3 AC Power 1.4 Safety instructions 10 10 10 10 2. Introduction 11 2.1 Features 2.2 DMX channel 11 11 3. Setup 11 3.1 Fuse replacement 3.2 Fixture linking 3.3 3-Pin to 5-Pin conversion chart 3.4 Setting up a DMX serial data link 3.5 Master/Slave fixture linking 3.6 Orientation 11 11 12 12 12 12 4. Operating instructions 13 4.1 Navigating the control panel 4.2 Menu map 4.3 User configurations 4.
1. Introduzione 1.1 Contenuto della confezione Proiettore Alimentazione Manuale d’uso 1 1 1 1.2 Istruzioni per l’apertura dell’imballo Appena ricevuto il prodotto, rimuovere l’imballo e controllare il contenuto assicurandosi che tutto sia presente all’interno e che sia in buone condizioni. Informare il venditore o il corriere se alcune parti sono danneggiate o se il cartone presenta segni di manomissione.
al punto di uscita dall'apparecchio. Il proiettore va pulito secondo le indicazioni riportate dal costruttore (vedere il capitolo Pulizia). Il proiettore deve essere posizionato lontano da qualsiasi sorgente di calore, incluso gli amplificatori. L’apparecchio deve essere riparato da personale qualificato nei casi in cui: A. il cavo di alimentazione o la spina siano danneggiati B. oggetti solidi e soprattutto liquidi siano caduti sopra o all’interno del proiettore C.
attraverso un controller DMX o un semplice collegamento master / slave. A seconda del numero di canali o del canale DMX assegnato, è possibile calcolare il numero massimo di proiettori collegabili. La lunghezza massima della catena DMX non deve superare i 500 m. Il numero massimo di proiettori raccomandati in ogni catena è 32.
4. Istruzioni operative 4.1 Pannello di controllo Accedere alle funzioni del pannello di controllo utilizzando i quattro pulsanti posti sotto al display. Quando è selezionata una funzione nel menù il display visualizzerà immediatamente la prima opzione disponibile. per selezionare premere . Premere il pulsante
(Menu principale) |_____________ (1° livello) (2° livello) |_____________ Add (Indirizzo DMX) |_____________ A.001 |_____________ …… |_____________ A.
4.3 Configurazione Indirizzamento DMX 1. Premere il pulsante
1. Preface 1.1 Packing list Par Light Power-line User Manual 1 pcs 1 base 1pcs 1.2 Unpacking instructions On receiving a fixture, carefully unpack the carton, check the contents to ensure that all parts are presented, and have been received in a good condition. Notify the shipper immediately and retain packing material for inspection if any parts appear damaged from shipping or the carton itself shows, sign of mishandling. Save the carton and all packing materials.
Cleaning -The fixture should be cleaned only as recommended by the manufacturer. See Cleaning for details. Heat -The appliance should be situated away from heat sources such as radiators, heat registers, stoves, or other appliances (including amplifiers) that produce heat. The fixture should be serviced by qualified service personnel when: A. The power-supply cord or the plug has been damaged. B. Objects have fallen, or liquid has been spilling to the appliance. C.
controller or to run synchronized on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support. Maximum recommended serial data link distance:500 meters(1640ft). Maximum recommended number of fixtures on a serial data link:32 fixtures. Data cabling To link fixtures together you must obtain data cables.
4. Operating instructions 4.1 Navigating the control panel Access control panel functions using the four panel buttons located directly under the Display. When a menu function is selected, the display will show immediately the first available option for the selected menu function. To select a menu item, press. Press the
(Main menu) st |_____________ (1 class option) |_____________ (2rd class option) Add (Address code setting) |_____________ A.001 |_____________ …… |_____________ A.
4.3 User configurations Addr-DMX Address Setting via control board 1. Tap the MENU button until Addr is displayed, press ENTER. 2. X will now be displayed, X represents the displayed address. Press the UP or DOWN buttons to find your desired address. 3. Press ENTER to confirm, and then press and hold the MENU button for at least three seconds to assign. SLA Master-Slave online mode: 1. SL00: slave mode 2. SL01: master mode SOUN Soundactive: 1. SOU1: sound control of strobe 2.
Proel S.p.A. Via alla Ruenia 37/43 64027 Sant'Omero (TE) ITALY Tel. +39 0861 81241 Fax. +39 0861 887862 Mail: info@proelgroup.com Web: www.proel.