Professional Digital Multimeter MT-1820 SELECT Hz/DUTY MAX/MIN AUTO POWER OFF RANGE HOLD REL/RS232 Hz Ω ˚C uA V mA hEF A OFF 10A ˚C uAmA MAX 10A 10sec FUSED hEF + VΩHz COM MAX 400mA FUSED MAX 1000V DC 750V AC MT-1820 CAT ll User ’s Manual
Index General 2 Open Package Inspection 2 Safety Note 2 Safety Symbol Description 4 Front Panel Description 5 Property 6 DC Voltage (DCV) 6 AC Voltage (ACV) 7 DC Current (DCA) 8 AC Current (ACA) 9 Resistance 11 Diode and Continuity Test 12 Capacitance (C) 12 Frequency (Hz) 13 Transistor Test 14 Temperature Test 15 Other Function & Instrument Maintenance 16
General The instrument is a high performance, high accuracy, 3 5/6 digit multi-meter, it uses the LCD with 33mm high figure to make the reading clear, the display simple and the operation convenient.
Warning To avoid endangering the safety of the users, should read the operation manual carefully before operation, and strictly abide by the safety warning information and operation description to use the instrument. 1. Caution to avoid the electric shock when measuring the voltage higher than 30V, the current higher than 10mA, AC Power Lines with Inductive Load and the AC Power Lines during the period of Electric Power Fluctuation. 2.
maximum voltage is printed on the front panel of the instrument, do not input the range limit specified to avoid the electric shock and instrument damage 9. Do not measure any voltage when connecting the test lead with the current terminal to avoid damaging the instrument and endangering the safety of the users. 10. Do not try to calibrate or repair the instrument, should operate it by the specially trained or qualified professional people. 11.
Front Panel Description 1 MT-1820 1. Instrument Model Number 2. LCD Display 2 3. HOLD: Date Hold button, press the button, the value is 3.1 3.5 held on LCD; Press the button again, exit the hold mode 3.3 3.2 3.6 3.4 and get into the normal measuring status. 4.
12. VΩHz input terminal: measure Voltage, Frequency/Duty Circle, Resistance, Capacitance, Diode and Continuity positive input terminal, insert the red test lead. Property General Feature 1-1 Display: LCD 1-2 Max Display: 5999 (3 5/6) counts automatic polarity display and unit display.
Note: a) Do not measure the voltage higher than DC 1000V or AC 750V. b) When measuring the high voltage, caution to avoid electric shock. Cut the connection between the test lead and tested circuit at once after measurement. C) At the Manual Range mode, if “OL” is displayed on LCD, it indicates the tested voltage value has exceeded the present range limit, please select the higher range to complete the measurement. Range Accuracy 600mV Resolution MT-1820 SELECT 0.1mV 60V ±(0.
frequency under the circumstance of magnetic disturbance, such as 220V/50Hz-400Hz,380V/50Hz~400Hz 3. Connect the test lead to the tested circuit in parallel, the polarity of the red test lead and the tested voltage value will be displayed on LCD simultaneously Note: a) Do not measure the voltage higher than DC 1000V or AC 750V. b) When measuring the high voltage, caution to avoid electric shock. Cut the connection between the test lead and tested circuit at once after measurement.
Note: a) Do not measure the current higher than 10A at Range 10A and higher than 6000uA at uA Range and higher than 600mA at mA Range, otherwise the fuse will be burnt out or the instrument will be damaged.
3. If “OL” is displayed on LCD, it indicates the tested current value has exceeded the present range limit, please select the higher range to complete the measurement. Note: a) Do not measure the current higher than 10A at Range 10A and higher than 600mA at mA Range b) Do not connect the test lead to any circuit in parallel when the test lead is inserted in the current input terminal, otherwise it is possible to damage the instrument or endanger the safety of the users.
Frequency response: 40-100Hz. Duty Circle Indication: (0.1%-99.9%) Resistance (Ω) 1. Turn the function/range selection knob to Ω, insert the red and black test lead separately to VΩHz and COM input terminal. 2. Connect the test lead to the tested resistance in parallel, the tested resistance value will be displayed on LCD 3. Auto Range mode is preset when turning on, press “RANGE” button to switch to Manual Range mode. 4.
Open circuit voltage: 400mV. Over range protection: 250V AC/DC peak value. Diode and Continuity Test 1. Turn the function/range selection knob to “ ”Range, displayed as the right pictures. 2. Insert the red and black test lead separately to VΩHz and COM input terminal. Press “SELECT” button to choose the Buzzer and Diode measurement function. 3. Connect the RED test lead to the positive pole of the tested diode, BLACK test lead to the negative pole. 4.
red and black test lead separately to VΩHz and COM input terminal. 2. Connect the test lead to the tested capacitor in parallel, the tested capacitor value will be displayed on LCD. 3. If “OL” is displayed on LCD, it indicates the test capacitor value has exceeded the present range limit or the capacitor is short-circuit, please select the higher range to complete the measurement. 4. Read the present test result from LCD.
Frequency (Hz) 1. Turn the function/range selection knob to Hz Range. Insert the red and black test lead separately to VΩHz and COM input terminal. 2. Connect the test lead to the tested signal source in parallel, Read the present test result from LCD. (Note: no Bar Graph display at this range) 3. When measuring Frequency, press “Hz/DUTY” button once to get into the mode of DUTY measurement, and press “Hz/DUTY” button again to return to the mode of Frequency measurement. 4.
1. Turn the function/range selection knob to “HFE” Range, displayed as the right picture. 2. Insert the accessory of Transistor test into the “uAmA ” 3. and “COM” input terminal, displayed as the picture.According to the model of the tested transistor, insert the accessory accordingly into the terminal of “EBC” of “NPN” or “PNP”. 4. Read the present test result from LCD.
Note: a) Without the signal input, LCD automatically displays the normal temperature. b) Do not replace the temperature sensor at will. Otherwise the accuracy can’t be assured. c) Do not input the voltage at Temperature Range, caution to avoid damaging the instrument. Range Accuracy Resolution -20˚C~400˚C ±(1.0%+50) 0.1˚C 400˚C~1000˚C ±(1.5%+15) 1˚C 0˚F~750˚F ±(1.0%+50d) 750˚F~1832˚F ±(1.
accessory of the instrument, and then can transmit the measuring data to PC, it is convenient to record, analyze, process and print the measuring results, etc. Please refer the details to the description in the software. • Instrument Maintenance This is a highly precise instrument, do not try to modify the inner circuit at will. 1. Keep the instrument dry, and keep it away form dust and shock. 2.
4. Please remove the test lead from the tested point and turn the power off before replacing the battery or fuse. The instruction manual is subject to chance without notice. The contents in the instruction manual are considered to be correct, if the users find any errors or pretermission, etc., please contact the manufacturer. The manufacturer hereby will not be responsible for any accident and damage caused by the improper operation.
目 錄 概述 20 開箱檢查 20 安全注意事項 20 安全符號說明 22 儀錶面板及按鍵功能說明 22 其他功能 23 特性 23 直流電壓(DCV) 24 交流電壓(ACV) 25 直流電流(DCA) 25 交流電流(ACA) 27 電阻 28 二極體及通斷測試 29 電容(C) 30 頻率(Hz) 30 三極管測量及溫度測量 31 溫度測量 32 通訊連接 32 儀錶保養 33 19
一.概述 MT-1820一種性能穩定、高可靠性3 5/6數位萬用表,儀錶採用33mm字高 LCD顯示器,讀數清晰,顯示直觀,操作方便,可用來測量直流電壓、交流電 壓、直流電流、交流電流、電阻、電容、頻率、占空比、三極管、二極體及通 斷測試;同時還設計有61段類比棒條顯示、單位符號顯示、資料保持、相對 值測量,帶USB電腦介面,自動/手動量程轉換、自動斷電及報警功能。整機 採用了一個能直接驅動LCD的4位元微處理器和雙積分A/D轉換積體電路,一 個提供高分辨力、高精度的數位顯示驅動,該表功能齊全,測量準確度高,使 用方便,是實驗室、工廠、無線電愛好者及家庭的理想工具。 二、開箱檢查 打開包裝箱取出儀錶,仔細檢查以下附件是否缺少或損壞,如有缺少或損壞請 立即與經銷商聯繫。 •數字多用表 一台 •使用說明書 一本 •表筆 一副 •溫度探頭(K型熱電偶) 一隻 •PC介面電纜 一根 •軟體光碟 一張 •三極管附件 一個 •鱷魚夾 一套 •防震套 1個 •皮盒 1個 三、安全注意事項 MT-1820符合IEC1010條款(國際電工委員會頒佈的安全標準)。使用污染等 級2的安全要求
量電力波動期間的交流電力線時, 謹防電擊。 2.測量前,檢查測量功能開關是否置於正確的檔位,,要檢查表筆是否可靠接 觸,是否正確連接、是否絕緣良好等,以避免電擊。 3.儀錶只有和所配備的表筆一起使用才符合安全標準要求。如表筆線破損 時,必需更換上同樣型號或者相同電氣規格的表筆線。 4.不要使用其他未經確認或未認可的保險管來更換儀錶內部的保險管。只能 換上同樣型號或相同規格的保險管。更換前,表筆必需離開被測量點,確保輸 入端無任何信號。 5.不要使用其他未經確認或未認可的電池來更換儀錶內的電池。只能換上同 型號或相同電氣規格的電池。更換前,表筆必需離開被測量點,確保輸入端 無任何信號。 6.在進行電氣測量時,身體切勿直接接觸大地,不要接觸可能存在地電勢裸露的 金屬端子、輸出口、引線夾等。通常使用的乾燥的衣服、膠鞋、膠墊以及其 他絕緣材料,保持你的身體與大地絕緣。 7.不要在高溫、高濕、易燃、易爆和強磁場環境中存放及使用。 8.
警告! 直流 高壓!危險! 交流 大地 交直流 雙重絕緣 符合歐洲工會指令 電池欠壓 保險絲 五、儀錶面板及按鍵功能說明 1. 儀錶型號 1 2. 61段類比棒條LCD屏顯示。 3. 功能按鍵:用於選擇各種測量功能。 3-1. HOLD:讀數保持,按此鍵顯示值被鎖定, 再按此鍵鎖定狀態被解除. 3-2. Hz/DUTY:頻率/占空比選擇鍵,在頻率 2 3.1 3.3 3.2 3.4 SELECT Hz/DUTY MAX/MIN AUTO POWER OFF 4 RANGE HOLD REL/RS232 Hz Ω 檔位元按此鍵可以在頻率和占空比之切換; 5 電壓或電流/頻率/占空比之間切換 6 7 8 3.5 3.6 ˚C uA V~ V mA A OFF 在交流電壓或交流電流檔位按此鍵可以在 3-3.
上消失,此時關閉RS232資料輸出,以此輪回。 4. 功能量程選擇開關,用於選擇各種測量功能和量程。 5. 10A電流輸入插孔:測量交直流電流10A檔的正輸入端,插入紅表筆。 6. uA/mA/˚C輸入孔:測量交直流微安、毫安培和溫度檔的正輸入端。 7. COM輸入孔:負輸入端,插入黑表筆。 8. VΩHz 輸入插孔:測量電壓、頻率/占空比、電阻、電容、二極體以及通斷 測試的正輸入端,插入紅表筆. 六、其他功能 1. 自動斷電 當儀錶停止使用15分鐘後,儀錶便自動斷電(關機),然後進入睡眠(關 機)狀態,斷電前一分鐘內置蜂鳴器會發出5聲提示,一分鐘後長響一聲進 入休眠(關機)狀態,若要重新啟動電源(開機),請按任意鍵或撥動開 關撥盤,均可重新開機。 2. 按“REL/RS232”鍵,為相對值測量,常按“REL/RS232”鍵,大於兩 秒,顯示幕上有RS232顯示,此時為為儀錶與電腦連接狀態,利用隨儀錶 所附的USB電腦介面線連儀錶到電腦上,可以對所測量的資料進行記錄、 分析、處理和列印。詳細請參考軟體中的說明。 3.
•儲存環境:-10~50℃,相對濕度<80% •電 源:兩節1.5V電池(“AAA”電池) •體積(尺寸):192mm×95mm×48mm(長×寬×高) •重 量:約390g(包括電池) 技術特性 •準確度:±(讀數的% + d數位),保證準確度環境溫度23±5℃,相對濕 度<75%, •校準保證期從出廠日起為一年。 八、直流電壓(DCV) 1. 將功能/量程開關旋至交直流電壓,紅黑表筆 分別插入“VΩHz”和“COM”孔中,按 MT-1820 SELECT “SELECT”鍵選擇直流電壓,如圖所示。 2. 儀錶的起始狀態為自動量程直流電壓模式, Hz/DUTY SELECT RANGE HOLD AUTO POWER OFF MAX/MIN REL/RS232 顯示“AUTO”符號,按“ RANGE“鍵, V Hz Ω ˚C uA V mA hEF A OFF 轉換為手動量程方式。 10A ˚C uAmA - 3.
750V交流峰值。 九、交流電壓(ACV) 1.將功能/量程開關旋至交直流電壓,按 “SELECT”選擇交流電壓,將紅黑 表筆分別插入“VΩHz”和“COM”。如下圖 2.儀錶的起始狀態為自動量程,顯示“AUTO”符號,按“RANGE“鍵, 轉換為手動量程方式。在自動或手動交流模式下按“Hz/DUTY”可測量頻 率/占空比測量,但此時頻響低,適用於磁場干擾環境下的高壓低頻測量, 如220V/50Hz-400Hz,380V/50Hz~400Hz。 3.將測式表筆接觸測試點並聯到被測電路上,紅色表筆線的極性和被測電壓值 將同時顯示在顯示幕幕上。 注 意: a) 不能測量高於DC1000V或AC750V的電壓。 b) 在測量高壓時,要特別注意避免觸電。並在測試完後表筆與被測電路立即 斷開。 MT-1820 量 程 準確度 SELECT 分辨力 V~ 1mV 6V SELECT Hz/DUTY MAX/MIN AUTO POWER OFF RANGE HOLD REL/RS232 60V ±(0.
3.
十一、交流電流(ACA) 1.將黑表筆插入“COM”孔中,紅表筆插入“uAmA ”或“10A”孔中,如 右圖所示。 2.將功能開關轉至電流檔,按“SELECT”鍵,選擇AC測量方式,然後將儀 錶串入被測回路中,被測電流值及紅表筆點的電流極性將同時顯示在螢幕 上 。 3.
頻率回應: 40~100Hz。 占空比顯示:(0.1%-99.9%) 十二、電阻(Ω) 1.將功能/量程開關旋至“Ω”檔,將紅黑表筆分入“VΩHz”和“COM”。 2.將表筆的測試端並聯到被測量電阻上被測電阻將顯示在顯示幕上。 3.開機為預設為自動量程,按“RANGE”鍵選擇手動量程操作方式。 4.如果顯示幕上顯示“OL”表明已經超過當前量程,請選擇更高的的量程來 完成。 注 意: a) 測電阻時,必須先將被測電路內所有的電源關斷,並將所有的電容充分放 電。 b) 在測量電阻時,任何電壓的出現都會引起測量讀數不准,如果超過250V 保護電壓,則有可能損壞和危及使用者的安全。 c) 在使用600Ω量程時,應先將表筆短路,測得引線電阻,然後在實測中減 去。 量 程 準確度 分辨力 600Ω ±(0.8%+5d) 0.1Ω 6kΩ ±(0.
2. 將紅、黑色表筆分別插入“VΩHz”和“COM”輸入 端,再按“SELECT”選擇蜂鳴器及二極體測量。 3.將紅色表筆接到二極體的正極,黑色表筆接到二極體的負極。 4.
十四、電容(C) 1.將功能開/量程開關旋到電容檔。將紅黑表筆線分別插 入“VΩHz”和“COM”輸入端。 2.將表筆線的測試端並聯到被測電容上,被測電容值將顯示在顯示幕上。 3.如果顯示幕上上顯“OL”,則表明被測電容值已超過當前量程或電容短 路,請選擇更高的量程檔測量。 4.從顯示幕上讀出當前的結果。 注 意: a) 在測電容時,必須先將被測線路內所有的電源斷開,並將所有的電容充分 放電。(注意:該檔無類比棒條顯示) b) 在測量大電容時,需要較長的時間,在100uF時約15秒。 C) 從完成所有的測量後,要立即斷開表筆與被測電路的連接。 量 程 準確度 + - 分辨力 4.7µF 25V MT-1820 40nF ±(5.0%+30d) 10pF REL/RS232 100pF 400nF SELECT Hz/DUTY MAX/MIN AUTO POWER OFF RANGE HOLD REL/RS232 4μF ±(3.5%+8d) 1nF Hz Ω ˚C uA V mA hEF A OFF 40μF 200μF 10nF ±(5.
注 意: a) 不要輸入高於60V的信號,否則可能損壞儀錶並危及人身安全。 b) 在完成所有的測量後,要立即斷開表筆與被測電路。 量 程 100Hz 準確度 分辨力 ±(0.5%+4d) 0.01Hz y 60Hz MT-1820 1000Hz 1Hz 10kHz 10Hz V~ Hz/DUTY SELECT Hz/DUTY MAX/MIN AUTO POWER OFF RANGE HOLD REL/RS232 100kHz 100Hz Hz Ω ˚C uA V mA hEF A OFF 1MHz 1kHz 20MHz 10kHz 10A ˚C uAmA - MAX 10A 10sec FUSED hEF + VΩHz COM MAX 400mA FUSED MAX 1000V DC 750V AC CAT ll 輸入靈敏度:1.0V。 MT-1820 超載保護:250V直流或交流峰值。 占空比顯示:(0.1%-99.
十七、溫度測量 1.將功能/量程選擇開關旋到溫度檔。 2.將溫度探頭的輸入端插入“COM”和“uAmA”孔中 , 正端插 入“uAmA”中 3.將溫度探頭的感應端置於被測物件的表面上,如右圖的水中 4.從顯示幕上讀出當前測量結果。 5.
詳細請參考軟體中的說明。 十九、儀錶保養 該儀錶是一台精密儀器,使用者不要隨意更改電路。 1.請注意防水,防塵、防摔。 2.不宜在高溫高濕、易燃易爆和強磁場的環境下存放、使用儀錶; 3.請使用濕布和溫和的清潔劑清潔儀錶外表,不要使用研磨劑及酒精等烈性 溶劑。 4.如果長時間不使用,應取出電池,防止電池漏液腐蝕儀錶; 5.注意電池使用情況,當LCD顯示出“ ”符號閃爍時,應更換電池; 步驟如下: 5-1.取出後蓋上固定電池的螺絲,退出電池門; 5-2.取下1.5V電池,換上兩個新的電池,雖然任何標準1.5V電池都可使用,但 為加長使用時間,最好使用鹼性電池; 5-3.裝上電池門,上緊螺絲; 5-4.保險絲更換:步驟同上。更換保險絲時,請使用規格、型號相同的保險 絲。 注 意: 1.不要將高於1000V直流或交流峰值電壓接入; 2.不要在電流檔、電阻檔、二極體檔和蜂鳴器檔上,去測量電壓值; 3.在電池沒有裝好或後蓋沒有上緊時,請不要使用此表; 4.
NOTE 34
寶工實業股份有限公司 PROKIT’S INDUSTRIES CO., LTD. http://www.prokits.com.tw E-mail : pk@mail.prokits.com.