Product specifications
D
C
A
B
A
D
C
B
Display Type
LT-4301TM
5.7"
65,536 colors
FLASH EPROM 16 MB
nvSRAM 128 KB *
2
nvSRAM 64 KB *
2
USB Mini B V2.0
4
20 or 12 *
4
10 or 6 *
4
50kHz Max. Pulse Output, 65kHz Max. PWM Output
0 or 2 *
4
0 or 2 *
4
0 or 2 *
4
Conforms to USB2.0
(
TYPE-A
)
x 1, Power Supply Voltage:
DC 5 V ±5 %, Output Current: 500 mA or less,
Communication Distance: 5 m
(
16.4 ft
)
or less
Conforms to USB1.1
(
TYPE-A
)
x 1, Power Supply Voltage: DC 5 V ±5 %,
Output Current: 500 mA or less, Communication Distance: 5 m
(
16.4 ft
)
or less
1
1
65kHz Max. Pulse Output, 65kHz Max. PWM Output *
9
DC24V
16
16
1 *
11
1 *
11
12
6
FLASH EPROM 6 MB
RS-232C/485, Asynchronous Transmission, Data Length: 7 or
8 bit, Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data
Transmission Speed: 2,400 bps to 115.2 kbps, Connector: RJ45
CAN-CiA (ISO 11898-2:2002 part2),
Connctor: D-sub9 (plug)
RS-232C/422/485, Asynchronous Transmission, Data Length: 7 or 8 bit,
Parity: none, Even or Odd, Stop Bit: 1 or 2 bit, Data Transmission Speed:
2,400 bps to 115.2 kbps, Connector: D-Sub9
(
plug
)
IEEE802.3i/IEEE802.3u, 10BASE-T/100BASE-TX, Connector: Modular jack
(
RJ-45
)
Monochrome
(
16 Levels
)
8 Levels
(
Adjusted with the touch panel
)
Resistive Film
(
analog
)
Monochrome
(
8 Levels
)
LT-4201TM
TFT
3.5"
LT-3300T
320 x 240 pixels
(
QVGA
)
LT-3300L LT-3301L LT-3201A
Monochrome Amber/Red
3.8"
Variable Area
Program Area
Number of Step *
3
Serial
(
COM1
)
CANopen (Master)
Ethernet
(
LAN
)
USB
(
TYPE-A
)
USB
(
mini B
)
Input
Output
Input
Output
Output
Input *
7
Temperature Input *
8
Output *
7
Control
Memory
Interface
Number of connecting devices
Built-in DIO
Special DIO *
5
(
Shared Use
)
Special DIO *
6
(
Exclusive Use
)
Built-in AIO
Monochrome
5.7"
EX Module interface *
10
AUX / Expansion Unit *
10
Rated Input Voltage
Display Size
Resolution
Display Colors
Brightness Control
Touch Panel Type
Application Memory *
1
Data Backup
Product Specifications Summary
Options
LT-3301L does not support Ethernet Interface.
The maximum thickness when three EX modules are connected:123.0mm [4.84in.].
The maximum thickness when two EX modules are connected:96.8 mm [3.81 in.]
LT-4301TM LT-4201TM
LT-3300T
/
L LT-3201A
External Dimensions / Panel Cut-Out
[
External Dimensions
/
Interfaces
]
Unit : mm
[
in.
]
[
External Dimensions
/
Interfaces
]
Unit : mm
[
in.
]
[
External Dimensions
/
Interfaces
]
Unit : mm
[
in.
]
[
Panel Cut-Out
]
Unit : mm
[
in.
]
[
Panel Cut-Out
]
Unit : mm
[
in.
]
[
Panel Cut-Out
]
Unit : mm
[
in.
]
[
Panel Cut-Out
]
Unit : mm
[
in.
]
76.5
[
3.01
]
5
[
0.20
]
21.5
[
0.85
]
21.5
[
0.85
]
92
[
3.62
]
130
[
5.12
]
104
[
4.09
]
167.4
[
6.59
]
135
[
5.31
]
144.6 [5.70]
134.6 [5.30]
123
[
4.84
]
5
[
0.19
]
77.6
[
3.06
]
DIO Interface
or less
Allowable Panel Thickness:
1.6
[
0.06
]
to 5.0
[
0.20
]
4/R3
[
0.12
]
123.5
-0
+1
[
4.86
]
156.0
- 0
+1
[
6.14
- 0
]
+0.04
Allowable Panel Thickness:
1.6
[
0.06
]
to 5.0
[
0.20
]
or less
4/R3
[
0.12
]
118.5
- 0
+1
[
4.67
- 0
]
+0.04
92.5
- 0
+1
[
3.64
- 0
]
+0.04
97.6
[
3.8
]
128
[
5.0
]
163
[
6.4
]
129.4
[
5.09
]
74.95±0.5
[
2.95±0.02
]
74.95±0.5
[
2.95±0.02
]
63.95
[
2.52
]
80
[
3.1
]
102
[
4.0
]
65.22
[
2.57
]
76.22±0.5
[
3.0±0.02
]
76.22±0.5
[
3.0±0.02
]
25.57
[1.01]25.57
[
1.01
]
LT4000M Series LT3000 Series
FLASH EPROM 132 KB
Equivalent to 15,000 steps
SRAM 64 KB *
2
[
External Dimensions
/
Interfaces
]
Unit : mm
[
in.
]
SRAM 128 KB *
2
Maintenance Options
For list of the maintenance options, if a product is
damaged or lost, please visit our website.
For further information, visit our website.
http://www.pro-face.com/product/hmi/lt4000m/option/option_other.html
LT-
330XX
LT-
4201TM
LT-
4301TM
"
**
" is changed with the version of software.
*1 LT4000M Series requires GP-Pro EX Ver.3.12 or later. *2 Group License consists of one set of Serial No./Key Code for installation. (Should be used in the same office. Only supports GP-Pro EX Ver.3.1 or later.)
*3 Purchase this product when installing GP-Pro EX in a second or subsequent PC. One license is required for each PC. *4 Only for units with Ethernet. *5 Includes the settings editor and Run time.
*6 Purchase this product when installing the settings editor and Run time in subsequent PCs. *7 Purchase this license when installing only Run time in subsequent PCs. One license is required for each PC.
Software
GP-Pro EX
GP-Pro EX Editor License
GP-Viewer EX
1 licence
10 licence
30 licence
PFXEXVW
PFXEXVWLS10
PFXEXVWLS30
Product Name Global Code Description
PFXEXEDV**
PFXEXEDLSV**
HMI screen editor & logic programming software *
1
GP-Pro EX Group License PFXEXGRPLS**** GP-Pro EX Editor Group License *
1
*
2
GP-Pro EX editor license *
3
*
4
License allowing a PC to access a LT in remote mode. *
4
Pro-Server EX Developer
Pro-Server EX Developer License
MES Action License
Pro-Server EX Runtime License
PFXEXSDLS
PFXEXSRLS
PFXEXMSLSV
**
PFXEXSDV** Software that connects a PC to a LT via Ethernet and collects and transmits data *
4
*
5
Pro-Server EX developer license *
4
*
6
Pro-Server EX Runtime license *
4
*
7
License key permitting Pro-Server EX to access a database
LT-
3201A
100KHz Max. High-speed Counter
(
with Synchronize Output
)
, Pulse Catch Input
*If rotating torque acted on a display module
is 2.5 N.m
(
22.12 in-lb
)
or more, use an
anti-rotation tee which is supplied with a LT
unit. The anti-rotation tee supports up to 6
N.m
(
53.10 in-lb
)
.
*If rotating torque acted on a display module
is 2.5 N.m
(
22.12 in-lb
)
or more, use an
anti-rotation tee which is supplied with a LT
unit. The anti-rotation tee supports up to 6
N.m
(
53.10 in-lb
)
.
*1 Capacity available for user application. *2 Rechargeable lithium battery for data back up. *3 Up to 60,000 steps can be converted in software. However, this reduces internal memory capacity
(
for screen data
)
by 1 MB.
*4 The number of Built-in digital and analog IOs differs between DIO type and Analog type. *5 Uses built-in DIO's points. *6 When using Pulse Output and PWM Output on LT4000M,
External I/O and a LT unit must share the same power supply. *7 Various voltage and current input ranges are supported. *8 RTD: PT100, PT1000, NI100 and NI1000. Thermocouple: J, K, R, B, S, T, E and N.
*9 For pulse outputs, when combining the number of CH and high-speed counters used, there is a limit to the maximum output frequency in the LT3000 Series. For details, please refer to GP-Pro EX Reference Manual.
*10 EX Module and Communication Expansion Unit cannot be used at the same time. *11 Up to three
(
LT-330xx
)
or two
(
LT-3201A
)
EX modules can be connected.
I
/
O Units
(
EX Module
/
CANopen unit
)
EX Module
Product Name
CANopen Master Unit
Global Code
Description
8-point sink-source shared expansion unit *
8
8-point relay output / 2-point common type expansion unit *
8
8-point transistor output sink type expansion unit *
8
8-point transistor output source type expansion unit *
8
16-point sink-source shared expansion unit *
8
16-point relay output / 2-point common type expansion unit *
8
16-point transistor output sink type expansion unit *
8
16-point transistor output source type expansion unit *
8
4-point input sink-source / 4-point relay output / 1 common mixed I/O unit *
8
2-ch analog input type expansion unit *
8
2-ch temperature input / 1-ch analog output type expansion unit *
8
2-ch analog input / 1-ch analog output expansion unit *
8
1-ch analog output type expansion unit *
8
4-ch Analog Input / Temperature Input Expansion Unit *
8
2-ch Analog output Expansion Unit *
8
4-ch Analog Input / 2-ch Analog Output Expansion Unit *
8
8-ch Temperature Input Expansion Unit *
8
16-point Input Sink-Source / 8-Point Relay Output Expansion Unit *
8
Master unit to connect to a slave unit supporting CANopen
Slave unit supporting CANopen with 12 digital inputs, 6 relay outputs and
2 transistor source outputs. Up to 7 units of EX modules can be connected.
*
8
PFXZLTEUDDI8DT
PFXZLTEUDRA8RT
PFXZLTEUDDO8UT
PFXZLTEUDDO8TT
PFXZLTEUDDI16DT
PFXZLTEUDRA16RT
PFXZLTEUDDO16UK
PFXZLTEUDDO16TK
PFXZLTEUDMM8DRT
PFXZLTEUAMI2HT
PFXZLTEUALM3LT
PFXZLTEUAMM3HT
PFXZLTEUAMO1HT
PFXZLTEUAMI4LT
PFXZLTEUAVO2HT
PFXZLTEUAMM6HT
PFXZLTEUARI8LT
PFXZLTEUDMM24DRF
PFXZC8EUCA1
PFXHTB1C0DM9LP
8-Point Input Module
8-Point Relay Output Module
8-Point Sink Output Module
8-Point Source Output Module
16-Point Input Module
16-Point Relay Output Module
16-Point Sink Output Module
16-Point Source Output Module
4-Point Input / 4-Point Relay Output Module
2-ch Analog Input Module
Thermocouple
(
Pt100 Input
)
/ 1-ch Analog Output Module
2-ch Analog Input / 1-ch Analog Output Module
1-ch Analog Output Module
4-ch Voltage, Current, Pt100 / Pt1000 / Ni100 / Ni1000 Input Module
2-ch Analog Output Module
4-ch Analog Input / 2-ch Analog Output Module
8-ch Temperature Pt100 / Pt1000 Input Module
16-point Input / 8-point Relay Output Module
CANopen Slave HTB Unit
LT-
330XX
LT-
4201TM
LT-
4301TM
LT-
3201A
*8 LT4000M Series reguires GP-Pro EX Ver.3.50 or later.
1.5 to 6
[
0.06to0.23
]
A B D
30.00
[1.18]
22.50
[0.88]
4.00
[0.15]
C
1.5 to 6
[0.06to0.23]
4.00
[0.15]
22.50
[0.88]
30.00
[1.18]
A B DC
Cable
EZ
Series
Adapter
Product Name
USB Transfer Cable
(
2m
)
USB Transfer Cable
(
USB Type A/mini B
)(
1.8 m
)
USB Panel-mount Extension Cable
(
USB mini B
)(
1m
)
USB Cable
(
5m
)
USB Front Cable
(
1m
)
USB-Serial
(
RS-232C
)
Conversion Cable
(
50cm
)
RS-232C Cable
(
5m
)
RJ45 RS-232C Cable
(
5m
)
RJ45 RS-485 Cable
(
5m
)
RS-422 Cable
(
5m
)
RS-422 Cable
(
5m
)
Display module/Rear module separation cable
(
3m
)
Display module/Rear module separation cable
(
5m
)
EZ Illuminated Switch
EZ Fingerprint Recognition Unit
COM port adapter
Terminal block conversion adapter
RS-232C Isolation Unit
Screen Protection Sheet
Environmentally-resistant Cover
Panel Cutout Adapter
Global Code
PFXZC3CBUSA1
PFXZC9USCBMB1
PFXZC9USEXMB1
PFXZC0CBUS1
PFXZC5CBUBEX1
PFXZC6CBCVUSR21
PFXZC3CBR251
PFXZLMCBRJR21
PFXZLMCBRJR81
PFXZC3CBR452
PFXZC3CBR451
PFXZXMADSM31
PFXZXMADSM51
PFXZCCEUSG1
PFXZCCEUSS1
PFXZC3ADCM1
PFXZC3ADR41
PFXZC3ADISR21
PFXZC3DS61
PFXZC6DS41
PFXZCBDS61
PFXZC4CNDCM1
PFXZC4AT61
Description
USB cable for transferring data such as screen data
(
host to host
)
Cable for transferring screen data from a PC
(
USB Type A
)
to the GP unit
(
USB mini B
)
.
Extension cable attaching to the USB
(
mini B
)
interface on the front side of the operation panel.
Connects a USB peripheral unit.
(
host to slave
)
The cable for extending the LT’s USB port
The conversion cable for using a LT's USB I/F as the Serial
(
RS-232C
)
I/F.
Connects a Modem only for the RS-232C communication method.
Interface cable for communication between a temperature controller/
various boards and the LT series via RS-232C.
Interface cable for communication between a temperature controller/
various boards and the LT series via RS-232C.
Cable with loose wires at one end for RS-232C connection between various hosts and the LT.
Cable with loose wires at one end for RS-485 connection between various hosts and the LT.
Interface cable for communication between a temperature controller/
various boards and the LT series via RS-422.
Interface cable for communication between a temperature controller/
various boards and the LT series via RS-422. <for a unit of terminal resistance 100>
Cable with hook to install a rear module on a DIN rail while connecting the
rear module to a separated display module
A unit of 5 illuminated switches with multiple color LED easily connected with HMI via USB
Fingerprint recognition unit easily connected with HMI via USB *
9
Pin assign conversion adapter connects optional RS-422
communication items to LT series unit’s COM1 port.
Conversion adapter converts a COM port to RS-422 terminal block.
Unit for providing isolated connection between a temperature controller/
various boards and the LT series. RS-232C and RS-422 are switchable.
Disposable, dirt-resistant sheet for the LT unit’s screen
(
5 pcs/set
)
Regarding grease and chemical application, do not remove the unit,
simply replace the environmental protection cover
(
5 pcs/set
)
Attachment required for installing a 5.7-inch display unit in the mounting
hole of LT Series
(
GLC150
)
.
Cable, Adapter, and other options.
LT-
330XX
LT-
4201TM
LT-
4301TM
LT-
3201A
*9 EZ Fingerprint Recognition Unit involves fingerprint technology. In some jurisdictions, this product may be subject to notification to and/or approval by relevant local regulatory authority prior to importing this product
into such jurisdictions and/or using this product in such jurisdictions. The jurisdictions which do not require such notification and/or approval as of December 1,2012 ("Non-regulated Jurisdictions") are as follows: Japan,
Taiwan, USA, Canada, Mexico, Brazil, Australia and Singapore.
05 06