UNDER CABINET RANGE HOOD INSTALLATION GUIDE AND USER MANUAL Item # QR001, QR003, QR006 QR009, QR014 & QR019
Table of Contents Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 Warranty . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 One Year Limited Warranty. . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Warranty Claim Procedure. . . . . . . . . . . .
Safety Information (continued) Cooking Safety Information WARNING: To reduce the risk of fire, use only metal duct 1. Never leave the range hood unattended when in use. work. Never use plastic duct work. 2. Never cook over open flames under the range hood. 3. Always turn the range hood on when cooking at high heat or when cooking flaming foods. WARNING: To reduce the risk of fire or electric shock, do not use this range hood with with any external solid state speed control device. 4.
Warranty ONE YEAR LIMITED WARRANTY A thorough inspection must be made before installation and any damage must be promptly reported. We will not be liable for failures or damage that could have been discovered or avoided by proper inspection and testing prior to installation. Conglom Kitchen & Bath warrants this product to be free from defects in materials or workmanship for one (1) year from the date of purchase.
Pre-Installation TOOLS REQUIRED Measuring tape Level Utility knife Pencil Tape Adjustable wrench Phillips screwdriver Flathead screwdriver Needle nose pliers Hammer Electric drill Safety goggles Safety gloves 5 CONGLOMKB.COM Please contact 1-877-333-0098 for further assistance.
Pre-Installation (continued) HARDWARE INCLUDED NOTE: Hardware not shown to actual size.
Pre-Installation (continued) PACKAGE CONTENTS A B D C F E Model QR001 Model QR006 Model QR014 I H G Part Description Quantity A Range Hood 1 G Charcoal Filter 1 H Damper 1 Part Description Quantity C Range Hood 1 G Charcoal Filter 1 H Damper 1 Part Description Quantity E Range Hood 1 H Damper 1 Model QR003 Model QR009 Model QR019 Part Description Quantity B Range Hood 1 G Charcoal Filter 1 H Damper 1 Part Description Quantity D Range Hood 1 H
Pre-Installation (continued) PLANNING INSTALLATION Number of people required: 2 or more WARNING: Always wear safety goggles and gloves during Carefully check the range hood for damage and for missing parts prior to installation. If there is any damage or if you are missing parts, do not proceed with the installation. Report damage and missing parts immediately. Do not dispose of packaging before you are satisfied with your new range hood. installation. 1.
Pre-Installation (continued) Venting Options (QR001, QR003 & QR006): a. Determine if your existing venting system is top venting or back venting, and ensure that the openings in the cabinet or wall for the damper and for power access are in appropriate locations and are of appropriate sizes, as per Fig. 5 if it is top vent or Fig. 6 if it is back vent. b. If this is a new installation, choose the venting method that suits your needs.
Pre-Installation (continued) Follow these guidelines when installing duct work: -- Your venting system must vent to the outdoors either horizontally through the back wall (13) or vertically through the roof (14) (refer to Fig. 8/Fig. 9/Fig. 10). For interior venting (the air does not vent outdoors), see Fig. 11. -- Use round metal duct work with a uniform diameter of 6 in. (152 mm). The total duct run in the venting system should be not more than 10.7 m (35 ft).
Pre-Installation (continued) WIRING CONNECTION REQUIREMENTS DANGER: Risk of electrical shock. This range hood must Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. be properly grounded. DANGER: Turn off the power circuit breaker or the OBSERVE ALL GOVERNING CODES AND ORDINANCES WARNINGS power switch on the junction box before installing this unit.
Pre-Installation (continued) PREPARING THE RANGE HOOD FOR INSTALLATION (only for models QR009, QR014 & QR019) -- Turn over the range hood (A) and place it on a protective surface, such as cardboard or a large towel. -- Remove the baffle nets (1) by pulling the handles (2). A 1 -- Remove the bottom panel (3) by removing the six screws (CC). Ensure you have a good grip on the bottom panel when removing the screws so they do not fall into the unit.
Installation 1 Removing the electrical knock-out hole 2 Removing the venting hole -- Choose the venting hole to remove for your installation type. Use the top hole (3) for a top venting installation and the back hole (4) for a back venting installation (not available in QR019) and top hole 5 for when you do not have the exterior exhaust, but will use the interior feature (available in units QR001, QR003 & QR006). WARNING: Always wear safety goggles and gloves during installation.
Installation (continued) 4 Installing the charcoal filter (skip this step if you are using an exterior venting) NOTICE: The charcoal filter should only be installed if you are not using a venting system. 10 -- Turn over the range hood (A) and place its top on a protective surface. 9 -- Unhook the charcoal filter support (9) from the support hook (10) and pull the charcoal filter support up. 10 -- Place the charcoal filter (B) under the charcoal filter support (9).
Installation (continued) 6 Installing the range hood DANGER: Turn off the power circuit breaker or the power switch on the junction box before installing this unit. Touching circuitry inside the range hood while it is energized will result in death or serious injury. DANGER: If installing this unit over a gas range, turn off AA the gas at the source before installing or servicing this unit. AA -- Lift the range hood (A) up under the cabinet to determine its final position.
Installation (continued) 7 Replacing the bottom panel (only for models QR009, QR014 & QR019) A -- Replace the bottom pane (B) on to the range hood body (A) by putting back the 6 screws (CC) that hold it in place. B CC 8 Replacing the filter/baffle nets Replace the baffle nets or filters by: A -- Inserting them first in the back groove of the range hood. -- Opening the clasp. 2 -- Putting the front of the filter in place. -- Releasing the clasp.
Operation Push button NOTICE: The fan and lights operate independently of each other. 1 2 Turning ON/OFF the unit -- To turn on the fan, press the appropriate speed control switch [Low Speed (2), Medium Speed (3), High Speed (4)] to select the desired level of power. Once a button is pressed, the previous speed mode will be cancelled. Turning ON/OFF the lights -- Press the light switch (5) to turn on and off the lights. -- Press the power switch (1) to turn off the fan. 1 2 3 4 5 17 CONGLOMKB.
Operation (continued) Push button / LCD Screen There are four buttons, ON/OFF, SPEED, LIGHT and CLOCK SETUP. The center screen will show the clock (12 hour). 1 1 2 3 4 2 Turning ON/OFF the unit -- Press (5) to turn on the power. When you turn the power on, the unit starts working in high speed, the clock indication on the center screen (3) will go off and "3" will be indicated on the screen. (During the operation speed indication will be indicated on the screen).
Maintenance DANGER: Turn off the power circuit breaker or the power switch on the junction box before performing maintenance. Touching circuitry inside the range hood while it is energized will result in death or serious injury. WARNING: Failure to replace worn out or damaged filters will increase the risk of fire. WARNING: Light bulbs can become extremely hot when turned on. Do not touch bulbs until they are switched off and cooled. Touching hot bulbs could cause serious burns.
Care and Cleaning RANGE HOOD WARNING: Failure to maintain basic standards of care and cleaning of the range hood will increase the risk of fire. The range hood should be cleaned (regularly internally and externally) to preserve its appearance and performance. Do: Do Not: -- Always clean in the direction of the grain (original polish lines). -- Do not use corrosive or abrasive detergents, steel wool, or scouring pads. These will scratch and damage the stainless steel surface.
Troubleshooting DANGER: Turn off the power circuit breaker or the power switch on the junction box before performing maintenance. Touching circuitry inside the range hood while it is energized will result in death or serious injury. Problem Solution The range hood will not operate. -- Check that the power supply cable and all electrical wiring are properly connected. -- Check that the power is turned on at the junction box or circuit breaker.
Specifications Model Dimensions 29.8 in. (757 mm) W QR001 18 in. (458 mm) D Rating 120~60Hz 1.6A Control Type Fan CFM Push Button 5 in. (127 mm) H Model Dimensions 29.8 in. (757 mm) W QR003 18 in. (458 mm) D Rating 120~60Hz 1.6A Control Type Fan CFM Push Button 5 in. (127 mm) H Model Dimensions 29.8 in. (757 mm) W QR006 18 in. (458 mm) D Rating 120~60Hz 1.6A Dimensions 29.8 in. (757 mm) W QR009 18 in. (458 mm) D Rating 120~60Hz 1.5A Push Button Dimensions 29.8 in.
Specifications (continued) WIRING DIAGRAM (only for models QR001, QR003 & QR009) WIRING DIAGRAM (only for model QR014) 23 CONGLOMKB.COM Please contact 1-877-333-0098 for further assistance.
Specifications (continued) WIRING DIAGRAM (only for model QR019) 24
Service Parts If you are missing parts or if you require replacement parts, please call our customer service team at 1-877-333-0098 (8:30 am – 5 pm, EST, Monday– Friday). Identify the required part(s) and have the part number(s) ready.
Service Parts (continued) Part Number Description Picture QR001 QR003 QR006 QR009 QR014 QR015 QR019 QR060 QHR109 Fan (93mm / 3-5/8in) - - - 1 1 - - - QHR111 Fan Set - - - - - 1 1 - QHR107 Fan - - - - - - - 1 QHR110 Fan Guard 1 1 1 1 1 - - - QHR115 Aluminum Filter (370 mm x 320 mm) 1 - - - - - - - QHR114 Aluminum Filter (366 mm x 344 mm) - 2 - - - - 2 - QHR113 Aluminum Filter (360 mm x 200 mm) - - - - - 2 - - QHR117 Baffle Filter (366
Imported by: St-Laurent, Québec, H4S 2C3 1-877-333-0098 www.conglomkb.com Made in China Retain this manual for future use.