Owner manual

Product Description
EASY TO USE
With the PIECAL Model 334 you can check, calibrate
and measure all your current signal instruments in a
4 to 20 milliamp DC loop. It can be used at any
access point in your loop. Source & Read 0.00 to
24.00 mA, Simulate a 2 Wire Transmitter or use the
PIECAL Model 334 to simultaneously power your 2
Wire Transmitter and measure its output. When
desired the PIECAL Model 334 can display current
in milliamps or percent of 4 to 20.
SOURCE MILLIAMPS
Calibrate recorders, digital indicators, stroke valves
or any instruments that get their input from a 4 to
20 mA loop. Easily set any value quickly to within
0.01 mA with the adjustable digital potentiometer
DIAL or use preset 4.00 mA (0.0%) and 20.00
mA (100.0%) EZ-CHECK™ settings.
RECALL OUTPUT SETTINGS
The EZ CHECK™ switch provides rapid checking of
4.00, 20.00 and any convenient third point between
0.00 to 24.00 mA.
CALIBRATE USING LOOP POWER
Check loop wiring and receivers by using the
PIECAL Model 334 in place of a 2 Wire transmitter.
Simulate a changing process input to check loop
response and control settings. The PIECAL Model
334 uses any loop power from 2 to 100V DC.
READ LOOP CURRENT
Check controller outputs or measure the milliamp signal anywhere in the loop. The
PIECAL Model 334 measures 0.00 to 52.00 mA signals with greater accuracy than
a typical multimeter. The PIECAL Model 334 can be easily switched to display
milliamps or percent of 4 to 20.
POWER & MEASURE 2 WIRE TRANSMITTERS
The PIECAL Model 334 can simultaneously output 24V DC to power any and all devices in a
process loop using the internal batteries and the internal switching power supply, while
measuring the output of a 2 Wire Transmitter and any other loop devices. This is handy for
checking the functionality of transmitters in the field or on the bench.
READ DC VOLTS
The PIECAL Model 334 can measure from -99.99 to +99.99 VDC with 10mV resolution. Use it to
check loop power supplies, I/V converters, chart recorders, 1 to 5 Volt signals, and any other
voltages within this range making it unnecessary to carry an additional multimeter.
PIECAL Model 334
4-20 mA Loop Calibrator
Operating Instructions
PIECAL Model 334
4-20 mA Loop Calibrator
Operating Instructions
Practical Instrument Electronics
82 East Main Street Suite 3.14 • Webster, NY 14580 Tel: 585.872.9350 • Fax: 585.872.2638 • sales@piecal.com • www.piecal.com
Copyright © 2011 All rights reserved • 334-9002 Rev E - 13 July 2011